Your browser doesn't support javascript.
loading
Ultra-stable Electrochemical Sensor for Detection of Caffeic Acid Based on Platinum and Nickel Jagged-Like Nanowires.
Wang, Jin; Yang, Beibei; Gao, Fei; Song, Pingping; Li, Lei; Zhang, Yangping; Lu, Cheng; Goh, M Cynthia; Du, Yukou.
Afiliación
  • Wang J; College of Chemistry, Chemical Engineering and Materials Science, Soochow University, Suzhou, 215123, People's Republic of China.
  • Yang B; College of Chemistry, Chemical Engineering and Materials Science, Soochow University, Suzhou, 215123, People's Republic of China.
  • Gao F; College of Chemistry, Chemical Engineering and Materials Science, Soochow University, Suzhou, 215123, People's Republic of China.
  • Song P; College of Chemistry, Chemical Engineering and Materials Science, Soochow University, Suzhou, 215123, People's Republic of China.
  • Li L; College of Biological, Chemical Sciences and Engineering, Jiaxing University, Jiaxing, Zhejiang, 314001, People's Republic of China. leili@mail.zjxu.edu.cn.
  • Zhang Y; College of Chemistry, Chemical Engineering and Materials Science, Soochow University, Suzhou, 215123, People's Republic of China.
  • Lu C; Department of Chemistry, Department of Materials Science and Engineering, Institute of Medical Science, University of Toronto, Toronto, ON, M5S 3H6, Canada. clu@chem.utoronto.ca.
  • Goh MC; Department of Chemistry, Department of Materials Science and Engineering, Institute of Medical Science, University of Toronto, Toronto, ON, M5S 3H6, Canada. cgoh@chem.utoronto.ca.
  • Du Y; College of Chemistry, Chemical Engineering and Materials Science, Soochow University, Suzhou, 215123, People's Republic of China. duyk@suda.edu.cn.
Nanoscale Res Lett ; 14(1): 11, 2019 Jan 08.
Article en En | MEDLINE | ID: mdl-30623249
ABSTRACT
Electrochemical sensors have the high sensitivity, fast response, and simple operation for applications in biological, medical, and chemical detection, but limited by the poor stability and high cost of the electrode materials. In this work, we used PtNi lagged-like nanowire for caffeic acid (CA) electrochemical detection. The removal of outer layer Ni during reaction process contributed to the rehabilitation of active Pt sites at the surface, leading to the excellent electrocatalytic behavior of CA sensing. Carbon-supported PtNi-modified glassy carbon electrode (PtNi/C electrode) showed a broad CA detecting range (from 0.75 to 591.783 µM), a low detection limit (0.5 µM), and excellent stability. The electrode preserved high electrocatalytic performance with 86.98% of the initial oxidation peak current retained after 4000 potential cycles in 0.5 mM caffeic acid solution. It also demonstrates excellent anti-interference capability and is ready for use in the real sample analysis.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Diagnostic_studies Idioma: En Revista: Nanoscale Res Lett Año: 2019 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Diagnostic_studies Idioma: En Revista: Nanoscale Res Lett Año: 2019 Tipo del documento: Article