Your browser doesn't support javascript.
loading
Highly selective and ultra-sensitive electrochemical sensor behavior of 3D SWCNT-BODIPY hybrid material for eserine detection.
Senocak, Ahmet; Köksoy, Baybars; Akyüz, Duygu; Koca, Atif; Klyamer, Darya; Basova, Tamara; Demirbas, Erhan; Durmus, Mahmut.
Afiliación
  • Senocak A; Department of Chemistry, Gebze Technical University, 41400 Gebze, Kocaeli, Turkey.
  • Köksoy B; Department of Chemistry, Gebze Technical University, 41400 Gebze, Kocaeli, Turkey.
  • Akyüz D; Department of Chemical Engineering, Marmara University, 34722 Göztepe, Turkey.
  • Koca A; Department of Chemical Engineering, Marmara University, 34722 Göztepe, Turkey.
  • Klyamer D; Nikolaev Institutes of Inorganic Chemistry SB RAS, Lavrentiev Pr. 3, Novosibirsk 630090, Russia; Novosibirsk State University, Pirogova Str. 2, Russia.
  • Basova T; Nikolaev Institutes of Inorganic Chemistry SB RAS, Lavrentiev Pr. 3, Novosibirsk 630090, Russia; Novosibirsk State University, Pirogova Str. 2, Russia.
  • Demirbas E; Department of Chemistry, Gebze Technical University, 41400 Gebze, Kocaeli, Turkey.
  • Durmus M; Department of Chemistry, Gebze Technical University, 41400 Gebze, Kocaeli, Turkey. Electronic address: durmus@gtu.edu.tr.
Biosens Bioelectron ; 128: 144-150, 2019 Mar 01.
Article en En | MEDLINE | ID: mdl-30660929
ABSTRACT
In this work, 4,4-difluoro-8-(4-hydroxyphenyl)- 2,6-diethynly-1,3,5,7-tetramethyl-4-bora-3a,4a-diaza-s-indacene (BODIPY) having double terminal ethynyl groups was synthesized. Three dimensional single walled carbon nanotube (SWCNT)-BODIPY hybrid material (3D SWCNT-BODIPY) was synthesized by the reaction of BODIPY bearing double terminal ethynyl groups with azido containing SWCNTs via "Click" reaction. The structural properties and electrochemical detection of eserine (a pesticide) on BODIPY functionalized SWCNTs as a three dimensional (3D) material were investigated. A glassy carbon electrode (GCE) was modified by 3D SWCNT-BODIPY hybrid material for the determination of eserine in the range of 0.25-2.25 µM. In the study by the square wave voltammetry (SWV), the bare GCE showed no response, while the new peak at - 0.6 V appeared in the case of the modified electrode. The detection limit and quantification were determined as 160 nM and 528 nM for eserine on the 3D SWCNT-BODIPY modified electrode, respectively. Eserine was also determined with a standard addition method in different brands of orange juices, and the recovery of eserine was obtained to be in the range of 102.09% and 103.22%. This study clearly indicates that the 3D SWCNT-BODIPY modified electrode tested as an electrochemical sensor was found to be highly selective and sensitive to eserine.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Fisostigmina / Compuestos de Boro / Técnicas Biosensibles / Técnicas Electroquímicas Tipo de estudio: Diagnostic_studies Idioma: En Revista: Biosens Bioelectron Asunto de la revista: BIOTECNOLOGIA Año: 2019 Tipo del documento: Article País de afiliación: Turquía

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Fisostigmina / Compuestos de Boro / Técnicas Biosensibles / Técnicas Electroquímicas Tipo de estudio: Diagnostic_studies Idioma: En Revista: Biosens Bioelectron Asunto de la revista: BIOTECNOLOGIA Año: 2019 Tipo del documento: Article País de afiliación: Turquía