Your browser doesn't support javascript.
loading
Comparison of Laser In Situ Keratomileusis Flap Morphology and Predictability by WaveLight FS200 Femtosecond Laser and Moria Microkeratome: An Anterior Segment Optical Coherence Tomography Study.
Eldaly, Zeiad H; Abdelsalam, Mahmoud A; Hussein, Mohamed S; Nassr, Mohamed A.
Afiliación
  • Eldaly ZH; Department of Ophthalmology, Assiut University, Assiut, Egypt. dr_ziadeldaly@aun.edu.eg.
  • Abdelsalam MA; Department of Ophthalmology, Assiut University, Assiut, Egypt.
  • Hussein MS; Department of Ophthalmology, Assiut University, Assiut, Egypt.
  • Nassr MA; Department of Ophthalmology, Assiut University, Assiut, Egypt.
Korean J Ophthalmol ; 33(2): 113-121, 2019 Apr.
Article en En | MEDLINE | ID: mdl-30977320
PURPOSE: To evaluate laser in situ keratomileusis (LASIK) flap thickness predictability and morphology by femtosecond (FS) laser and microkeratome (MK) using anterior segment optical coherence tomography. METHODS: Fifty-two candidates for the LASIK procedure were stratified into two groups: FS laser-assisted (Allegretto FS-200) and MK flap creation (Moria 2). Flap thickness was determined at five points. The side-cut angle was measured in three directions at the margin interface. LASIK flap assessment was performed one month postoperatively by Spectralis anterior segment optical coherence tomography. RESULTS: Fifty-two patients (93 eyes) were recruited; 49 eyes were stratified to the FS group and 44 eyes to the MK group. The FS group had relatively even flap configurations, and the MK group had meniscus-shaped flaps. Mean differences between planned and actual flap thickness were 12.93 ± 8.89 and 19.91 ± 5.77 µm in the FS and MK groups, respectively. In thin flaps (100 to 110 µm), there was a significant disparity between the two groups (7.80 ± 4.71 and 19.44 ± 4.46 µm in the FS and MK groups, respectively). However, in thicker flaps (130 µm), comparable flap thickness disparity was achieved (18.54 ± 9.52 and 20.83 ± 5.99 µm in the FS and MK groups, respectively). Mean side-cut angle was 74.29 ± 5.79 degrees and 32.34 ± 4.94 degrees in the FS and MK groups, respectively. CONCLUSIONS: Comparable flap thickness predictability was achieved in thicker flaps (130 µm), while the FS laser technique yielded a more predictable result in thinner flaps (100 to 110 µm). Different flap morphology was observed in meniscus flaps in MK-LASIK and flap morphology in FS-LASIK.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Refracción Ocular / Colgajos Quirúrgicos / Queratomileusis por Láser In Situ / Tomografía de Coherencia Óptica / Láseres de Excímeros / Segmento Anterior del Ojo / Miopía Tipo de estudio: Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Adult / Female / Humans / Male Idioma: En Revista: Korean J Ophthalmol Asunto de la revista: OFTALMOLOGIA Año: 2019 Tipo del documento: Article País de afiliación: Egipto Pais de publicación: Corea del Sur

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Refracción Ocular / Colgajos Quirúrgicos / Queratomileusis por Láser In Situ / Tomografía de Coherencia Óptica / Láseres de Excímeros / Segmento Anterior del Ojo / Miopía Tipo de estudio: Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Adult / Female / Humans / Male Idioma: En Revista: Korean J Ophthalmol Asunto de la revista: OFTALMOLOGIA Año: 2019 Tipo del documento: Article País de afiliación: Egipto Pais de publicación: Corea del Sur