Setting-up a Real-Time Air Quality Forecasting system for Serbia: a WRF-Chem feasibility study with different horizontal resolutions and emission inventories.
Podrascanin, Zorica.
Afiliación
  • Podrascanin Z; Faculty of Sciences, Department of Physics, University of Novi Sad, Dositej Obradovic Square 3, Novi Sad, Serbia. zorica.podrascanin@df.uns.ac.rs.
Environ Sci Pollut Res Int ; 26(17): 17066-17079, 2019 Jun.
Article en En | MEDLINE | ID: mdl-30997641
In this paper, the influence of the horizontal model grid size and anthropogenic gridded emissions on the air quality forecast in Serbia was analyzed using the online-coupled Weather Research and Forecasting model with Chemistry (WRF-Chem). For that purpose, six simulations were performed. The model horizontal grid size was 20 × 20 km, 10 × 10 km, and 5 × 5 km. Two anthropogenic gridded emission inventories with different grid sizes were used, the global RETRO (REanalysis of the TROpospheric chemical composition) and the EMEP (The European Monitoring and Evaluation Program) for each model horizontal grid size. The modeled O3, NO2, and PM10 concentrations in all six simulations were compared with the measured hourly data at the Serbian Environmental Protection Agency (SEPA) stations and an EMEP station during August 2016. The analysis shows that the influence of the model grid size is larger on PM10 than on the O3 and NO2 concentration. The concentration of O3 and PM10 has a similar dependence on the emissions and the model grid size, while NO2 has a larger dependence on the emission than on the model grid size. The simulation with the 5 × 5 km grid size and the EMEP anthropogenic emissions has optimal performance compared with the measured concentration. In this optimal simulation, the modeled O3 concentrations overestimated the measured values at 3 stations and underestimated the measured values at 2 stations. At most stations, the modeled NO2 concentrations underestimated the measured values. The modeled PM10 concentrations highly underestimated the measured values at all stations.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Ozono / Monitoreo del Ambiente / Contaminantes Atmosféricos / Contaminación del Aire / Modelos Teóricos / Dióxido de Nitrógeno Tipo de estudio: Prognostic_studies País/Región como asunto: Europa Idioma: En Revista: Environ Sci Pollut Res Int Asunto de la revista: SAUDE AMBIENTAL / TOXICOLOGIA Año: 2019 Tipo del documento: Article Pais de publicación: Alemania

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Ozono / Monitoreo del Ambiente / Contaminantes Atmosféricos / Contaminación del Aire / Modelos Teóricos / Dióxido de Nitrógeno Tipo de estudio: Prognostic_studies País/Región como asunto: Europa Idioma: En Revista: Environ Sci Pollut Res Int Asunto de la revista: SAUDE AMBIENTAL / TOXICOLOGIA Año: 2019 Tipo del documento: Article Pais de publicación: Alemania