Femoral fracture classification in the Swedish Fracture Register - a validity study.
Knutsson, Sara Brandt; Wennergren, David; Bojan, Alicja; Ekelund, Jan; Möller, Michael.
Afiliación
  • Knutsson SB; Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden. sara.knutsson@vgregion.se.
  • Wennergren D; Department of Orthopaedics, Sahlgrenska University Hospital Gothenburg, SE-413 45 Gothenburg, Mölndal, Sweden. sara.knutsson@vgregion.se.
  • Bojan A; Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.
  • Ekelund J; Department of Orthopaedics, Sahlgrenska University Hospital Gothenburg, SE-413 45 Gothenburg, Mölndal, Sweden.
  • Möller M; Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.
BMC Musculoskelet Disord ; 20(1): 197, 2019 May 08.
Article en En | MEDLINE | ID: mdl-31068172
ABSTRACT

BACKGROUND:

A total of more than 270,000 fractures are registered in the Swedish Fracture Register (SFR), a national quality register. Fractures are classified following the AO/OTA classification, commonly by a junior doctor. As a step in the process of validating the data in the SFR, several studies of the accuracy of the fracture classification have already been published. The aim of this study was to evaluate the accuracy of femoral fracture classification in the SFR.

METHODS:

One hundred and eighteen femur fractures were randomly selected from the SFR. Three experienced orthopaedic surgeons individually classified these fractures on two separate occasions and a gold standard classification was established. This classification was compared with the original classification in the SFR. Inter- and intraobserver agreement was calculated.

RESULTS:

The agreement between the classification in the SFR and the gold standard classification was kappa = 0.65 for the AO/OTA group and kappa = 0.83 for the AO/OTA type. This corresponds to substantial and almost perfect agreement, according to Landis and Koch. The kappa values for interobserver agreement ranged from 0.64-0.76 for the AO/OTA group and 0.76-0.85 for the AO/OTA type. The kappa values for intraobserver agreement ranged from 0.79-0.81 for the AO/OTA group and 0.91-0.93 for the AO/OTA type.

CONCLUSIONS:

The classification of femoral fractures in the Swedish Fracture Register is substantial (AO/OTA group) to almost perfect (AO/OTA type) and as accurate as in previous studies. The present study also shows that the agreement between the SFR classification and a gold standard classification is in the same range of agreement as between experienced raters. In contrast to previous studies, the classifications in the SFR are made by an unselected group of mostly inexperienced classifiers. The results indicate that the fracture classification in a national quality register can be accurate enough to permit the evaluation of fracture treatment in specific groups of fractures.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Sistema de Registros / Fracturas del Fémur Tipo de estudio: Diagnostic_studies Límite: Adolescent / Adult / Aged / Aged80 / Female / Humans / Male / Middle aged País/Región como asunto: Europa Idioma: En Revista: BMC Musculoskelet Disord Asunto de la revista: FISIOLOGIA / ORTOPEDIA Año: 2019 Tipo del documento: Article País de afiliación: Suecia

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Sistema de Registros / Fracturas del Fémur Tipo de estudio: Diagnostic_studies Límite: Adolescent / Adult / Aged / Aged80 / Female / Humans / Male / Middle aged País/Región como asunto: Europa Idioma: En Revista: BMC Musculoskelet Disord Asunto de la revista: FISIOLOGIA / ORTOPEDIA Año: 2019 Tipo del documento: Article País de afiliación: Suecia
...