Your browser doesn't support javascript.
loading
Wearable Environmental Monitor To Quantify Personal Ambient Volatile Organic Compound Exposures.
Fung, Alexander G; Rajapakse, Maneeshin Y; McCartney, Mitchell M; Falcon, Alexandria K; Fabia, Fauna M; Kenyon, Nicholas J; Davis, Cristina E.
Afiliación
  • Fung AG; Mechanical and Aerospace Engineering , University of California, Davis , One Shields Avenue , Davis , California 95616 , United States.
  • Rajapakse MY; Mechanical and Aerospace Engineering , University of California, Davis , One Shields Avenue , Davis , California 95616 , United States.
  • McCartney MM; Mechanical and Aerospace Engineering , University of California, Davis , One Shields Avenue , Davis , California 95616 , United States.
  • Falcon AK; Mechanical and Aerospace Engineering , University of California, Davis , One Shields Avenue , Davis , California 95616 , United States.
  • Fabia FM; Mechanical and Aerospace Engineering , University of California, Davis , One Shields Avenue , Davis , California 95616 , United States.
  • Kenyon NJ; Department of Internal Medicine , University of California, Davis , 4150 V Street, Suite 3400, Sacramento , California 95817 , United States.
  • Davis CE; Center for Comparative Respiratory Biology and Medicine , University of California, Davis , Davis , California 95616 , United States.
ACS Sens ; 4(5): 1358-1364, 2019 05 24.
Article en En | MEDLINE | ID: mdl-31074262
ABSTRACT
Air pollution can cause acute and chronic health problems. It has many components, and one component of interest is volatile organic compounds (VOCs). While the outdoor environment may have regulations regarding exposure limits, the indoor environment is often unregulated and VOCs often appear in greater concentrations in the indoor environment. Therefore, it is equally critical to monitor both the indoor and outdoor environments for ambient chemical levels that an individual person is exposed to. While a number of different chemical detectors exist, most lack the ability to provide portable monitoring. We have developed a portable and wearable sampler that collects environmental VOCs in a person's immediate "exposure envelope" onto custom micro-preconcentrator chips for later benchtop analysis. The system also records ambient temperature and humidity and the GPS location during sampling, and the chip cartridges can be used in sequence over time to complete a profile of individual chemical exposure over the course of hours/days/weeks/months. The system can be programmed to accumulate sample for various times with varying periodicity. We first tested our sampler in the laboratory by completing calibration curves and testing saturation times for various common chemicals. The sampler was also tested in the field by collecting both indoor and outdoor personal exposure samples. Additionally under IRB approval, a teenaged volunteer wore the sampler for 5 days during which it sampled periodically throughout a 12 h period each day and the volunteer replaced the micro-preconcentrator chip each day.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Monitoreo del Ambiente / Contaminantes Atmosféricos / Compuestos Orgánicos Volátiles / Dispositivos Electrónicos Vestibles Límite: Adolescent / Adult / Humans Idioma: En Revista: ACS Sens Año: 2019 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Monitoreo del Ambiente / Contaminantes Atmosféricos / Compuestos Orgánicos Volátiles / Dispositivos Electrónicos Vestibles Límite: Adolescent / Adult / Humans Idioma: En Revista: ACS Sens Año: 2019 Tipo del documento: Article País de afiliación: Estados Unidos
...