Rapid and Automated Detection of Six Contaminants in Milk Using a Centrifugal Microfluidic Platform with Two Rotation Axes.
Chen, Yiqi; Zhu, Yunzeng; Shen, Minjie; Lu, Ying; Cheng, Jing; Xu, Youchun.
Afiliación
  • Chen Y; State Key Laboratory of Membrane Biology, Department of Biomedical Engineering, School of Medicine , Tsinghua University , Beijing 100084 , China.
  • Zhu Y; Collaborative Innovation Center for Diagnosis and Treatment of Infectious Diseases , Hangzhou 310003 , China.
  • Shen M; State Key Laboratory of Membrane Biology, Department of Biomedical Engineering, School of Medicine , Tsinghua University , Beijing 100084 , China.
  • Lu Y; Collaborative Innovation Center for Diagnosis and Treatment of Infectious Diseases , Hangzhou 310003 , China.
  • Cheng J; State Key Laboratory of Membrane Biology, Department of Biomedical Engineering, School of Medicine , Tsinghua University , Beijing 100084 , China.
  • Xu Y; Collaborative Innovation Center for Diagnosis and Treatment of Infectious Diseases , Hangzhou 310003 , China.
Anal Chem ; 91(12): 7958-7964, 2019 06 18.
Article en En | MEDLINE | ID: mdl-31124361
ABSTRACT
Antibiotic residues and illegal additives are among the most common contaminants in milk and other dairy products, and they have become essential public health concerns. To ensure the safety of milk, rapid and convenient screening methods are highly desired. Here, we integrated microarray technology into a microfluidic device to achieve rapid, sensitive, and fully automated detection of chloramphenicol, tetracyclines, enrofloxacin, cephalexin, sulfonamides, and melamine in milk on a centrifugal microfluidic platform with two rotation axes. All the liquid reagent for the immunoassay was prestored in the reagent chambers of the microdevice and can be released on demand. The whole detection can be automatically accomplished within 17 min, and the limits of detection were defined as 0.92, 1.01, 1.83, 1.14, 1.96, and 7.80 µg/kg for chloramphenicol, tetracycline (a typical drug of tetracyclines), enrofloxacin, cephalexin, sulfadiazine (a typical drug of sulfonamides), and melamine, respectively, satisfying the national standards for maximum residue limits in China. Raw milk samples were used to test the performance of the current immunoassay system, and the recovery rates in the repeatability tests ranged from 80 to 111%, showing a good performance. In summary, the immunoassay system established in this study can simultaneously detect six contaminants of four samples in a fully automated, cost-effective, and easy-to-use manner and thus has great promise as a screening tool for food safety testing.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Rotación / Contaminación de Alimentos / Centrifugación / Leche / Dispositivos Laboratorio en un Chip / Análisis de los Alimentos Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Animals Idioma: En Revista: Anal Chem Año: 2019 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Rotación / Contaminación de Alimentos / Centrifugación / Leche / Dispositivos Laboratorio en un Chip / Análisis de los Alimentos Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Animals Idioma: En Revista: Anal Chem Año: 2019 Tipo del documento: Article País de afiliación: China
...