Your browser doesn't support javascript.
loading
Custom 3-Dimensional Printed Ultrasound-Compatible Vascular Access Models: Training Medical Students for Vascular Access.
Sheu, Alexander Y; Laidlaw, Grace L; Fell, John C; Triana, Brian P; Goettl, Christopher S; Shah, Rajesh P.
Afiliación
  • Sheu AY; Division of Vascular and Interventional Radiology, Stanford University School of Medicine, Stanford, California.
  • Laidlaw GL; Section of Interventional Radiology, University of Washington, Seattle, Washington.
  • Fell JC; Center for Immersive and Simulation-Based Learning, Stanford University School of Medicine, Stanford, California.
  • Triana BP; Division of Vascular and Interventional Radiology, Stanford University School of Medicine, Stanford, California.
  • Goettl CS; Division of Vascular and Interventional Radiology, Stanford University School of Medicine, Stanford, California.
  • Shah RP; Division of Vascular and Interventional Radiology, Stanford University School of Medicine, Stanford, California; Veterans Affairs Palo Alto Health Care System, MC114, 3801 Miranda Avenue, Palo Alto, CA 94304. Electronic address: Rajesh.Shah2@va.gov.
J Vasc Interv Radiol ; 30(6): 922-927, 2019 Jun.
Article en En | MEDLINE | ID: mdl-31126603
PURPOSE: To generate 3-dimensional (3D) printed ultrasound (US)-compatible vascular models (3DPVAM) and test them for noninferiority in training medical students in femoral artery access. MATERIALS AND METHODS: A 3DPVAM of normal femoral artery (FA) anatomy was developed from an anonymized computerized tomography (CT) examination. Students were randomized to a 3DPVAM or a commercial model (CM) simulation experience (SE) for US-guided FA access. Students completed a pre-SE questionnaire ranking their self-confidence in accessing the artery on a 5-point Likert scale. A standardized SE was administered by interventional radiology faculty or trainees. Students completed a post-SE questionnaire ranking comfort with FA access on a Likert scale. Student questionnaire results from the 3DPVAM group were compared with those from the CM group by using chi-square, Wilcoxon signed-rank, and noninferiority analyses. RESULTS: Twenty-six and twenty-three students were randomized to 3DPVAM and commercial model training, respectively. A total of 76.9% of 3DPVAM trainees and 82.6% of CM trainees did not feel confident performing FA access prior to the SE. In both groups, training increased student confidence by 2 Likert points (3DPVAM: P < 0.001; CM P < 0.001). The confidence increase in 3DPVAM trainees was noninferior to that in CM trainees (P < 0.001). CONCLUSIONS: Generation of a custom-made 3DPVAM is feasible, producing comparable subjective training outcomes to those of CM. Custom-made 3D-printed training models, including incorporation of more complex anatomical configurations, could be used to instruct medical students in procedural skills.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Estudiantes de Medicina / Cateterismo Periférico / Radiografía Intervencional / Radiología Intervencionista / Educación de Pregrado en Medicina / Arteria Femoral / Impresión Tridimensional / Modelos Anatómicos / Modelos Cardiovasculares Tipo de estudio: Clinical_trials / Qualitative_research Límite: Humans Idioma: En Revista: J Vasc Interv Radiol Asunto de la revista: ANGIOLOGIA / RADIOLOGIA Año: 2019 Tipo del documento: Article Pais de publicación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Estudiantes de Medicina / Cateterismo Periférico / Radiografía Intervencional / Radiología Intervencionista / Educación de Pregrado en Medicina / Arteria Femoral / Impresión Tridimensional / Modelos Anatómicos / Modelos Cardiovasculares Tipo de estudio: Clinical_trials / Qualitative_research Límite: Humans Idioma: En Revista: J Vasc Interv Radiol Asunto de la revista: ANGIOLOGIA / RADIOLOGIA Año: 2019 Tipo del documento: Article Pais de publicación: Estados Unidos