Your browser doesn't support javascript.
loading
Benefits of deep learning for delineation of organs at risk in head and neck cancer.
van der Veen, J; Willems, S; Deschuymer, S; Robben, D; Crijns, W; Maes, F; Nuyts, S.
Afiliación
  • van der Veen J; KU Leuven, Dept. Oncology, Laboratory of Experimental Radiotherapy, & UZ Leuven, Radiation Oncology, Belgium.
  • Willems S; KU Leuven, Dept. ESAT, Processing Speech and Images (PSI), & UZ Leuven, Medical Imaging Research Center, Belgium.
  • Deschuymer S; KU Leuven, Dept. Oncology, Laboratory of Experimental Radiotherapy, & UZ Leuven, Radiation Oncology, Belgium.
  • Robben D; KU Leuven, Dept. ESAT, Processing Speech and Images (PSI), & UZ Leuven, Medical Imaging Research Center, Belgium; Icometrix, B-3000 Leuven, Belgium.
  • Crijns W; KU Leuven, Dept. Oncology, Laboratory of Experimental Radiotherapy, & UZ Leuven, Radiation Oncology, Belgium.
  • Maes F; KU Leuven, Dept. ESAT, Processing Speech and Images (PSI), & UZ Leuven, Medical Imaging Research Center, Belgium.
  • Nuyts S; KU Leuven, Dept. Oncology, Laboratory of Experimental Radiotherapy, & UZ Leuven, Radiation Oncology, Belgium. Electronic address: sandra.nuyts@uzleuven.be.
Radiother Oncol ; 138: 68-74, 2019 09.
Article en En | MEDLINE | ID: mdl-31146073
ABSTRACT
PURPOSE/

OBJECTIVE:

Precise delineation of organs at risk (OARs) in head and neck cancer (HNC) is necessary for accurate radiotherapy. Although guidelines exist, significant interobserver variability (IOV) remains. The aim was to validate a 3D convolutional neural network (CNN) for semi-automated delineation of OARs with respect to delineation accuracy, efficiency and consistency compared to manual delineation. MATERIAL/

METHODS:

16 OARs were manually delineated in 15 new HNC patients by two trained radiation oncologists (RO) independently, using international consensus guidelines. OARs were also automatically delineated by applying the CNN and corrected as needed by both ROs separately. Both delineations were performed two weeks apart and blinded to each other. IOV between both ROs was quantified using Dice similarity coefficient (DSC) and average symmetric surface distance (ASSD). To objectify network accuracy, differences between automated and corrected delineations were calculated using the same similarity measures.

RESULTS:

Average correction time of the automated delineation was 33% shorter than manual delineation (23 vs 34 minutes) (p < 10-6). IOV improved significantly with network initialisation for nearly all OARs (p < 0.05), resulting in decreased ASSD averaged over all OARs from 1.9 to 1.2 mm. The network achieved an accuracy of 90% and 84% DSC averaged over all OARs for RO1 and RO2 respectively, with an ASSD of 0.7 and 1.5 mm, which was in 93% and 73% of the cases lower than the IOV.

CONCLUSION:

The CNN developed for automated OAR delineation in HNC was shown to be more efficient and consistent compared to manual delineation, which justify its implementation in clinical practice.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Órganos en Riesgo / Aprendizaje Profundo / Neoplasias de Cabeza y Cuello Tipo de estudio: Etiology_studies / Guideline / Risk_factors_studies Límite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Radiother Oncol Año: 2019 Tipo del documento: Article País de afiliación: Bélgica

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Órganos en Riesgo / Aprendizaje Profundo / Neoplasias de Cabeza y Cuello Tipo de estudio: Etiology_studies / Guideline / Risk_factors_studies Límite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Radiother Oncol Año: 2019 Tipo del documento: Article País de afiliación: Bélgica