  • Dunn LK; From the Department of Anesthesiology (L.K.D., A.M.K., K.T.F., A.J.B., S.R.C., J.F.P., C.J.K., J.L.H., E.C.N.) the Department of Neurosurgery (E.C.N.), University of Virginia, Charlottesville, Virginia the Department of Nutrition and Exercise Physiology, Washington State University, Spokane, Washington (S.T.).
Anesthesiology ; 131(2): 401-409, 2019 Aug.
Article en En | MEDLINE | ID: mdl-31149926
BACKGROUND: Residency programs utilize night float systems to adhere to duty hour restrictions; however, the influence of night float on resident sleep has not been described. The study aim was to determine the influence of night float on resident sleep patterns and quality of sleep. We hypothesized that total sleep time decreases during night float, increases as residents acclimate to night shift work, and returns to baseline during recovery. METHODS: This was a single-center observational study of 30 anesthesia residents scheduled to complete six consecutive night float shifts. Electroencephalography sleep patterns were recorded during baseline (three nights), night float (six nights), and recovery (three nights) using the ZMachine Insight monitor (General Sleep Corporation, USA). Total sleep time; light, deep, and rapid eye movement sleep; sleep efficiency; latency to persistent sleep; and wake after sleep onset were observed. RESULTS: Mean total sleep time ± SD was 5.9 ± 1.9 h (3.0 ± 1.2.1 h light; 1.4 ± 0.6 h deep; 1.6 ± 0.7 h rapid eye movement) at baseline. During night float, mean total sleep time was 4.5 ± 1.8 h (1.4-h decrease, 95% CI: 0.9 to 1.9, Cohen's d = -1.1, P < 0.001) with decreases in light (2.2 ± 1.1 h, 0.7-h decrease, 95% CI: 0.4 to 1.1, d = -1.0, P < 0.001), deep (1.1 ± 0.7 h, 0.3-h decrease, 95% CI: 0.1 to 0.4, d = -0.5, P = 0.005), and rapid eye movement sleep (1.2 ± 0.6 h, 0.4-h decrease, 95% CI: 0.3 to 0.6, d = -0.9, P < 0.001). Mean total sleep time during recovery was 5.4 ± 2.2 h, which did not differ significantly from baseline; however, deep (1.0 ± 0.6 h, 0.4-h decrease, 95% CI: 0.2 to 0.6, d = -0.6, P = 0.001 *, P = 0.001) and rapid eye movement sleep (1.2 ± 0.8 h, 0.4-h decrease, 95% CI: 0.2 to 0.6, d = -0.9, P < 0.001 P < 0.001) were significantly decreased. CONCLUSIONS: Electroencephalography monitoring demonstrates that sleep quantity is decreased during six consecutive night float shifts. A 3-day period of recovery is insufficient for restorative sleep (rapid eye movement and deep sleep) levels to return to baseline.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Trastornos del Sueño del Ritmo Circadiano / Horario de Trabajo por Turnos / Internado y Residencia / Anestesiología Tipo de estudio: Observational_studies Límite: Adult / Female / Humans / Male Idioma: En Revista: Anesthesiology Año: 2019 Tipo del documento: Article Pais de publicación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Trastornos del Sueño del Ritmo Circadiano / Horario de Trabajo por Turnos / Internado y Residencia / Anestesiología Tipo de estudio: Observational_studies Límite: Adult / Female / Humans / Male Idioma: En Revista: Anesthesiology Año: 2019 Tipo del documento: Article Pais de publicación: Estados Unidos