Impact of daily soft-tissue image guidance to prostate on pelvic lymph node (PLN) irradiation for prostate patients receiving SBRT.
Tyagi, Neelam; Hipp, Elizabeth; Cloutier, Michelle; Charas, Tomer; Fontenla, Sandra; Mechalakos, James; Hunt, Margie; Zelefsky, Michael.
Afiliación
  • Tyagi N; Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, USA.
  • Hipp E; Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, USA.
  • Cloutier M; Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, USA.
  • Charas T; Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York, NY, USA.
  • Fontenla S; Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, USA.
  • Mechalakos J; Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, USA.
  • Hunt M; Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, USA.
  • Zelefsky M; Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York, NY, USA.
J Appl Clin Med Phys ; 20(7): 121-127, 2019 Jul.
Article en En | MEDLINE | ID: mdl-31206236
ABSTRACT

PURPOSE:

To determine the impact of using fiducial match for daily image-guidance on pelvic lymph node (PLN) coverage for prostate cancer patients receiving stereotactic body radiation therapy (SBRT).

METHODS:

Thirty patients underwent SBRT treatment to the prostate and PLN from 2014 to 2016. Each patient received either 800cGy × 5 or 500cGy × 5 to the prostate and 500cGy × 5 to the PLN. A 5 mm clinical target volume (CTV)-to-planning target volume (PTV) margin around the PLN was used for planning. Two registrations with planning computed tomography (PCT) for each of the daily cone beam CTs (CBCTs) were performed a rigid registration to fiducials and to the bony anatomy. The average translational difference between fiducial and bony match as well as percentage of fractions with differences > 5mm were calculated. Changes in bladder and rectal volume as well as center-of-mass (COM) position from simulation parameters, and their correlation with translational difference were also evaluated. The dosimetric impact of the translational differences was calculated by shifting the plan isocenter.

RESULTS:

The average translational difference between fiducial and bony match was 0.06 ± 0.82, 2.1 ± 4.1, -2.8 ± 4.3, and 5.5 ± 4.2 mm for lateral, vertical, longitudinal, and vector directions. The average change in bladder and rectal volume from simulation was -67.2 ± 163.04 cc (-12 ± 52%) and -1.6 ± 18.75 (-2 ± 30%) cc. The average change in COM of bladder from the simulation position was 0.34 ± 2.49, 4.4 ± 8.1, and -3.9 ± 7.5 mm along the LR, AP, and SI directions. The corresponding COM change for the rectum was 0.17 ± 1.9, 1.34 ± 3.5, and -0.6 ± 5.2 mm.

CONCLUSIONS:

The 5 mm margin covered ~75% of fractions receiving PLN irradiation with SBRT, daily CBCT and fiducial-guided setup. The dosimetric impact on PLN coverage was significant in 19% of fractions or 25% of patients. A larger translational shift was due to variation in rectal volume and changes in COM position of the bladder and rectum. A consistent bladder positioning and/or rectum filling compared with presimulation volume were essential for adequate coverage of PLN in a hypofractionated treatment regime.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Pelvis / Neoplasias de la Próstata / Procesamiento de Imagen Asistido por Computador / Planificación de la Radioterapia Asistida por Computador / Radiocirugia / Radioterapia Guiada por Imagen / Ganglios Linfáticos Tipo de estudio: Etiology_studies / Guideline / Prognostic_studies Límite: Humans / Male Idioma: En Revista: J Appl Clin Med Phys Asunto de la revista: BIOFISICA Año: 2019 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Pelvis / Neoplasias de la Próstata / Procesamiento de Imagen Asistido por Computador / Planificación de la Radioterapia Asistida por Computador / Radiocirugia / Radioterapia Guiada por Imagen / Ganglios Linfáticos Tipo de estudio: Etiology_studies / Guideline / Prognostic_studies Límite: Humans / Male Idioma: En Revista: J Appl Clin Med Phys Asunto de la revista: BIOFISICA Año: 2019 Tipo del documento: Article País de afiliación: Estados Unidos