Your browser doesn't support javascript.
loading
Incorporation of 3D stereophotogrammetry as a reliable method for assessing scar volume in standard clinical practice.
Peake, Mitchell; Pan, Kristen; Rotatori, R Maxwell; Powell, Heather; Fowler, Laura; James, Laura; Dale, Elizabeth.
Afiliación
  • Peake M; Shriners Hospitals for Children, Cincinnati, United States; University of Cincinnati College of Medicine, United States.
  • Pan K; Shriners Hospitals for Children, Cincinnati, United States; University of Cincinnati College of Medicine, United States.
  • Rotatori RM; Shriners Hospitals for Children, Cincinnati, United States; University of Cincinnati College of Medicine, United States.
  • Powell H; The Ohio State University Wexner College of Medicine, United States.
  • Fowler L; Shriners Hospitals for Children, Cincinnati, United States.
  • James L; Shriners Hospitals for Children, Cincinnati, United States.
  • Dale E; Shriners Hospitals for Children, Cincinnati, United States; University of Cincinnati College of Medicine, United States; University of Cincinnati, Department of Plastic, Reconstructive, and Burn Surgery, United States. Electronic address: elizabeth.dale@uc.edu.
Burns ; 45(7): 1614-1620, 2019 11.
Article en En | MEDLINE | ID: mdl-31208769
ABSTRACT
Significant disfigurement and dysfunction is caused by hypertrophic scarring, a prevalent complication of burn wounds. A lack of objective tools in the assessment of scar parameters makes evaluation of scar treatment modalities difficult. 3D stereophotogrammetry, obtaining measurements from 3D photographs, represents a method to quantitate scar volume, and a 3D camera may have use in clinical practice. To validate this method, scar models were created and photographed with a 3D camera. Measurements from 3D image analysis of these scar models were compared to physical measurements of scar model volume. Reliability of 3D image analysis was assessed with both scar models and burn patient scars. Measurements of scar models by two independent observers were compared to determine inter-rater reliability, and measurements from 3D images of burn patient hypertrophic scars were compared to determine the consistency of the method between observers. The time taken for patient photography was recorded. No significant differences were found between the two methods of volume calculation (p = 0.89), and a plot of the differences showed agreement between the methods. The correlation coefficient between the two observers' measurements of scar model volume was 0.92, and the intra-class correlation coefficient for patient scar volume was 0.998, showing good reliability. The time required to capture 3D photographs ranged from 2 to 6 min per patient, showing the potential for this tool to be efficiently incorporated into clinical practice. 3D stereophotogrammetry is a valid method to reliably measure scar volume and may be used to objectively measure efficacy of scar treatment modalities to track scar development and resolution.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Fotogrametría / Cicatriz Hipertrófica / Imagenología Tridimensional Tipo de estudio: Etiology_studies Límite: Animals / Child / Female / Humans / Male Idioma: En Revista: Burns Asunto de la revista: TRAUMATOLOGIA Año: 2019 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Fotogrametría / Cicatriz Hipertrófica / Imagenología Tridimensional Tipo de estudio: Etiology_studies Límite: Animals / Child / Female / Humans / Male Idioma: En Revista: Burns Asunto de la revista: TRAUMATOLOGIA Año: 2019 Tipo del documento: Article País de afiliación: Estados Unidos