Your browser doesn't support javascript.
loading
Comparison of apical irrigant solution extrusion among conventional and laser-activated endodontic irrigation.
Vidas, Jelena; Snjaric, Damir; Braut, Alen; Carija, Zoran; Persic Bukmir, Romana; De Moor, Roeland J G; Brekalo Prso, Ivana.
Afiliación
  • Vidas J; Department of Endodontics and Restaurative Dentistry, School of Dentistry, University of Rijeka, Brace Branchetta 20, 51 000, Rijeka, Croatia. jelena.vidas@yahoo.com.
  • Snjaric D; Department of Endodontics and Restaurative Dentistry, School of Dentistry, University of Rijeka, Brace Branchetta 20, 51 000, Rijeka, Croatia.
  • Braut A; Department of Endodontics and Restaurative Dentistry, School of Dentistry, University of Rijeka, Brace Branchetta 20, 51 000, Rijeka, Croatia.
  • Carija Z; Department of Fluid Mechanics and Computational Engineering, Technical Faculty, University of Rijeka, Vukovarska ul. 58, Rijeka, Croatia.
  • Persic Bukmir R; Department of Endodontics and Restaurative Dentistry, School of Dentistry, University of Rijeka, Brace Branchetta 20, 51 000, Rijeka, Croatia.
  • De Moor RJG; Department of Endodontology, Dental School, Ghent University Hospital, Ghent University, C. Heymanslaan 10/1P8/route 25, 9000, Ghent, Belgium.
  • Brekalo Prso I; Department of Endodontics and Restaurative Dentistry, School of Dentistry, University of Rijeka, Brace Branchetta 20, 51 000, Rijeka, Croatia.
Lasers Med Sci ; 35(1): 205-211, 2020 Feb.
Article en En | MEDLINE | ID: mdl-31321596
ABSTRACT
The aim of this study was to determine the amount of extruded endodontic irrigant among needle-syringe irrigation (NSI) and laser-activated irrigation (LAI) regimens. Twenty extracted maxillary central incisors were prepared utilizing GT professional rotary files (size 40, taper 0.06). Irrigation was performed with two 27 G irrigation needles (notched open ended (ON) and single side vented (SV)) each at two different irrigant volumetric flow rates (VFR)-0.05 ml/s (3 ml/min) and 0.10 ml/s (6 ml/min). LAI was performed with ErYAG (erbium-doped yttrium aluminum garnet) using different fiber types (X-Pulse-14/400 cylindrical tip, Preciso- 14/300 flat cylindrical tip, PIPS- 14/400 quartz tapered tip). The ErYAG laser with a wavelength of 2940 nm (Lightwalker AT, Fotona, Ljubljana, Slovenia) was used according to the following protocol 10 mJ per pulse, 15 Hz, pulse duration 50 µs. Irrigation time was 60 s for all protocols. Precision syringe pump (PSP) maintained constant irrigant volumetric flow rate. Apically extruded irrigant was collected and net weighed for each protocol (N = 10). Data were analyzed by t tests and Kruskal-Wallis. All LAI regimens had statistically significant lower irrigant extrusion compared with NSI except for the SV 27 G needle used with 0.05 ml/s VFR when compared with the Preciso fiber tip (p = 0,230). The largest amount of extruded irrigant was with the ON 27 G needle at the 0.10 ml/s VFR, while the smallest was after LAI with PIPS fiber tip. The lower quantity of apically extruded irrigant during LAI (X-Pulse and PIPS) points out a safer endodontic irrigation method compared with conventional irrigations.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Irrigantes del Conducto Radicular / Preparación del Conducto Radicular / Láseres de Estado Sólido Límite: Humans Idioma: En Revista: Lasers Med Sci Asunto de la revista: BIOTECNOLOGIA / RADIOLOGIA Año: 2020 Tipo del documento: Article País de afiliación: Croacia

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Irrigantes del Conducto Radicular / Preparación del Conducto Radicular / Láseres de Estado Sólido Límite: Humans Idioma: En Revista: Lasers Med Sci Asunto de la revista: BIOTECNOLOGIA / RADIOLOGIA Año: 2020 Tipo del documento: Article País de afiliación: Croacia