Implementation of a Nonlinear Microscope Based on Stimulated Raman Scattering.
Ranjan, Rajeev; Indolfi, Maurizio; Ferrara, Maria Antonietta; Sirleto, Luigi.
Afiliación
  • Ranjan R; National Research Council, Institute for Microelectronics and Microsystems, Naples Unit, Italy.
  • Indolfi M; National Research Council, Institute for Microelectronics and Microsystems, Naples Unit, Italy.
  • Ferrara MA; National Research Council, Institute for Microelectronics and Microsystems, Naples Unit, Italy.
  • Sirleto L; National Research Council, Institute for Microelectronics and Microsystems, Naples Unit, Italy; luigi.sirleto@cnr.it.
J Vis Exp ; (149)2019 07 06.
Article en En | MEDLINE | ID: mdl-31329172
ABSTRACT
Stimulated Raman scattering (SRS) microscopy uses near-infrared excitation light; therefore, it shares many multi-photon microscopic imaging properties. SRS imaging modality can be obtained using commercial laser-scanning microscopes by equipping with a non-descanned forward detector with proper bandpass filters and lock-in amplifier (LIA) detection scheme. A schematic layout of a typical SRS microscope includes the following two pulsed laser beams, (i.e., the pump and probe directed in a scanning microscope), which must be overlapped in both space and time at the image plane, then focused by a microscope objective into the sample through two scanning mirrors (SMs), which raster the focal spot across an x-y plane. After interaction with the sample, transmitted output pulses are collected by an upper objective and measured by a forward detection system inserted in an inverted microscope. Pump pulses are removed by a stack of optical filters, whereas the probe pulses that are the result of the SRS process occurring in the focal volume of the specimen are measured by a photodiode (PD). The readout of the PD is demodulated by the LIA to extract the modulation depth. A two-dimensional (2D) image is obtained by synchronizing the forward detection unit with the microscope scanning unit. In this paper, the implementation of an SRS microscope is described and successfully demonstrated, as well as the reporting of label-free images of polystyrene beads with diameters of 3 µm. It is worth noting that SRS microscopes are not commercially available, so in order to take advantage of these characteristics, the homemade construction is the only option. Since SRS microscopy is becoming popular in many fields, it is believed that this careful description of the SRS microscope implementation can be very useful for the scientific community.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Espectrometría Raman / Microscopía Óptica no Lineal Idioma: En Revista: J Vis Exp Año: 2019 Tipo del documento: Article País de afiliación: Italia

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Espectrometría Raman / Microscopía Óptica no Lineal Idioma: En Revista: J Vis Exp Año: 2019 Tipo del documento: Article País de afiliación: Italia