Evaluation of a 3D-printed heterogeneous anthropomorphic head and neck phantom for patient-specific quality assurance in intensity-modulated radiation therapy.
Kadoya, Noriyuki; Abe, Kota; Nemoto, Hikaru; Sato, Kiyokazu; Ieko, Yoshiro; Ito, Kengo; Dobashi, Suguru; Takeda, Ken; Jingu, Keiichi.
Afiliación
  • Kadoya N; Department of Radiation Oncology, Tohoku University Graduate School of Medicine, 1-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi, 980-8574, Japan. kadoya.n@rad.med.tohoku.ac.jp.
  • Abe K; Department of Radiation Oncology, Tohoku University Graduate School of Medicine, 1-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi, 980-8574, Japan.
  • Nemoto H; Department of Radiation Oncology, Tokyo Metropolitan Cancer and Infectious Diseases Center Komagome Hospital, Tokyo, 113-8677, Japan.
  • Sato K; Department of Radiation Oncology, Tohoku University Graduate School of Medicine, 1-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi, 980-8574, Japan.
  • Ieko Y; Department of Radiology, Tohoku University Hospital, Sendai, Miyagi, 980-8574, Japan.
  • Ito K; Department of Radiation Oncology, Tohoku University Graduate School of Medicine, 1-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi, 980-8574, Japan.
  • Dobashi S; Department of Radiation Oncology, Yamagata University Faculty of Medicine, Yamagata, Japan.
  • Takeda K; Department of Radiation Oncology, Tohoku University Graduate School of Medicine, 1-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi, 980-8574, Japan.
  • Jingu K; Department of Radiological Technology, School of Health Sciences, Faculty of Medicine, Tohoku University, Miyagi, 980-8574, Japan.
Radiol Phys Technol ; 12(3): 351-356, 2019 Sep.
Article en En | MEDLINE | ID: mdl-31364005
We evaluated an anthropomorphic head and neck phantom with tissue heterogeneity, produced using a personal 3D printer, with quality assurance (QA), specific to patients undergoing intensity-modulated radiation therapy (IMRT). Using semi-automatic segmentation, 3D models of bone, soft tissue, and an air-filled cavity were created based on computed tomography (CT) images from patients with head and neck cancer treated with IMRT. For the 3D printer settings, polylactide was used for soft tissue with 100% infill. Bone was reproduced by pouring plaster into the cavity created by the 3D printer. The average CT values for soft tissue and bone were 13.0 ± 144.3 HU and 439.5 ± 137.0 HU, respectively, for the phantom and 12.1 ± 124.5 HU and 771.5 ± 405.3 HU, respectively, for the patient. The gamma passing rate (3%/3 mm) was 96.1% for a nine-field IMRT plan. Thus, this phantom may be used instead of a standard shape phantom for patient-specific QA in IMRT.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Garantía de la Calidad de Atención de Salud / Fantasmas de Imagen / Radioterapia de Intensidad Modulada / Impresión Tridimensional / Cabeza / Cuello Tipo de estudio: Evaluation_studies Límite: Humans Idioma: En Revista: Radiol Phys Technol Asunto de la revista: BIOFISICA / RADIOLOGIA Año: 2019 Tipo del documento: Article País de afiliación: Japón Pais de publicación: Japón

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Garantía de la Calidad de Atención de Salud / Fantasmas de Imagen / Radioterapia de Intensidad Modulada / Impresión Tridimensional / Cabeza / Cuello Tipo de estudio: Evaluation_studies Límite: Humans Idioma: En Revista: Radiol Phys Technol Asunto de la revista: BIOFISICA / RADIOLOGIA Año: 2019 Tipo del documento: Article País de afiliación: Japón Pais de publicación: Japón