Your browser doesn't support javascript.
loading
Diagnostic and grading accuracy of 18F-FDOPA PET and PET/CT in patients with gliomas: a systematic review and meta-analysis.
Xiao, Jiarui; Jin, Yizi; Nie, Ji; Chen, Fukun; Ma, Xuelei.
Afiliación
  • Xiao J; Department of Biotherapy, Cancer Center, State Key Laboratory of Biotherapy, West China Hospital, Sichuan University and Collaborative Innovation Center, No.37, Guoxue Alley, Chengdu, 610041, Sichuan, China.
  • Jin Y; Medical College, Soochow University, Suzhou, 215006, Jiangsu, China.
  • Nie J; Medical College, Soochow University, Suzhou, 215006, Jiangsu, China.
  • Chen F; Department of Biotherapy, Cancer Center, State Key Laboratory of Biotherapy, West China Hospital, Sichuan University and Collaborative Innovation Center, No.37, Guoxue Alley, Chengdu, 610041, Sichuan, China.
  • Ma X; West China School of Medicine, Sichuan University, Chengdu, 610041, Sichuan, China.
BMC Cancer ; 19(1): 767, 2019 Aug 05.
Article en En | MEDLINE | ID: mdl-31382920
ABSTRACT

BACKGROUND:

Positron emission tomography (PET) and PET/computed tomography (PET/CT) imaging with 3,4-dihydroxy-6-[18F] fluoro-L-phenylalanine (18F-FDOPA) has been used in the evaluation of gliomas. We performed a meta-analysis to obtain the diagnostic and grading accuracy of 18F-FDOPA PET and PET/CT in patients with gliomas.

METHODS:

PubMed, Embase, Cochrane Library and Web of Science were searched through 13 May 2019. We included studies reporting the diagnostic performance of 18F-FDOPA PET or PET/CT in glioma patients. Pooled sensitivity, specificity, and area under the summary receiver operating characteristic (SROC) curve were calculated from eligible studies on a per-lesion basis.

RESULTS:

Eventually, 19 studies were included. Across 13 studies (370 patients) for glioma diagnosis, the pooled sensitivity and specificity of 18F-FDOPA PET and PET/CT were 0.90 (95%CI 0.86-0.93) and 0.75 (95%CI 0.65-0.83). Across 7 studies (219 patients) for glioma grading, 18F-FDOPA PET and PET/CT showed a pooled sensitivity of 0.88 (95%CI 0.81-0.93) and a pooled specificity of 0.73 (95%CI 0.64-0.81).

CONCLUSIONS:

18F-FDOPA PET and PET/CT demonstrated good performance for diagnosing gliomas and differentiating high-grade gliomas (HGGs) from low-grade gliomas (LGGs). Further studies implementing standardized PET protocols and investigating the grading parameters are needed.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Neoplasias Encefálicas / Radioisótopos de Flúor / Tomografía de Emisión de Positrones / Tomografía Computarizada por Tomografía de Emisión de Positrones / Glioma Tipo de estudio: Diagnostic_studies / Guideline / Prognostic_studies / Systematic_reviews Límite: Adolescent / Adult / Aged / Child / Female / Humans / Male / Middle aged Idioma: En Revista: BMC Cancer Asunto de la revista: NEOPLASIAS Año: 2019 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Neoplasias Encefálicas / Radioisótopos de Flúor / Tomografía de Emisión de Positrones / Tomografía Computarizada por Tomografía de Emisión de Positrones / Glioma Tipo de estudio: Diagnostic_studies / Guideline / Prognostic_studies / Systematic_reviews Límite: Adolescent / Adult / Aged / Child / Female / Humans / Male / Middle aged Idioma: En Revista: BMC Cancer Asunto de la revista: NEOPLASIAS Año: 2019 Tipo del documento: Article País de afiliación: China