Your browser doesn't support javascript.
loading
Molecular imaging of oxidative stress using an LED-based photoacoustic imaging system.
Hariri, Ali; Zhao, Eric; Jeevarathinam, Ananthakrishna Soundaram; Lemaster, Jeanne; Zhang, Jianjian; Jokerst, Jesse V.
Afiliación
  • Hariri A; Department of NanoEngineering, University of California, San Diego, 9500 Gilman Drive, La Jolla, CA, 92093, USA.
  • Zhao E; Department of NanoEngineering, University of California, San Diego, 9500 Gilman Drive, La Jolla, CA, 92093, USA.
  • Jeevarathinam AS; Department of NanoEngineering, University of California, San Diego, 9500 Gilman Drive, La Jolla, CA, 92093, USA.
  • Lemaster J; Department of NanoEngineering, University of California, San Diego, 9500 Gilman Drive, La Jolla, CA, 92093, USA.
  • Zhang J; Key Laboratory of Synthetic and Natural Functional Molecule Chemistry of the Ministry of Education, Modern Separation Science Key Laboratory of Shaanxi Province, College of Chemistry & Materials Science, Northwest University, Xi'an, China.
  • Jokerst JV; Department of NanoEngineering, University of California, San Diego, 9500 Gilman Drive, La Jolla, CA, 92093, USA. jjokerst@ucsd.edu.
Sci Rep ; 9(1): 11378, 2019 08 06.
Article en En | MEDLINE | ID: mdl-31388020
ABSTRACT
LED-based photoacoustic imaging has practical value in that it is affordable and rugged; however, this technology has largely been confined to anatomic imaging with limited applications into functional or molecular imaging. Here, we report molecular imaging reactive oxygen and nitrogen species (RONS) with a near-infrared (NIR) absorbing small molecule (CyBA) and LED-based photoacoustic imaging equipment. CyBA produces increasing photoacoustic signal in response to peroxynitrite (ONOO-) and hydrogen peroxide (H2O2) with photoacoustic signal increases of 3.54 and 4.23-fold at 50 µM of RONS at 700 nm, respectively. CyBA is insensitive to OCl-, ˙NO, NO2-, NO3-, tBuOOH, O2-, C4H9O˙, HNO, and ˙OH, but can detect ONOO- in whole blood and plasma. CyBA was then used to detect endogenous RONS in macrophage RAW 246.7 cells as well as a rodent model; these results were confirmed with fluorescence microscopy. Importantly, CyB suffers photobleaching under a NdYAG laser but the signal decrease is <2% with the low-power LED-based photoacoustic system and the same radiant exposure time. To the best of our knowledge, this is the first report to describe molecular imaging with an LED-based photoacoustic scanner. This study not only reveals the sensitive photoacoustic detection of RONS but also highlights the utility of LED-based photoacoustic imaging.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Especies Reactivas de Oxígeno / Estrés Oxidativo / Especies de Nitrógeno Reactivo / Imagen Molecular / Técnicas Fotoacústicas Límite: Animals Idioma: En Revista: Sci Rep Año: 2019 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Especies Reactivas de Oxígeno / Estrés Oxidativo / Especies de Nitrógeno Reactivo / Imagen Molecular / Técnicas Fotoacústicas Límite: Animals Idioma: En Revista: Sci Rep Año: 2019 Tipo del documento: Article País de afiliación: Estados Unidos