Your browser doesn't support javascript.
loading
How to perform electroanatomic mapping-guided cardiac resynchronization therapy using Carto 3 and ESI NavX three-dimensional mapping systems.
Huang, Henry D; Sharma, Parikshit S; Nayak, Hemal M; Serafini, Nicholas; Trohman, Richard G.
Afiliación
  • Huang HD; Division of Cardiology, Rush University Medical Center, 1717 W. Congress Parkway, Suite 332, Kellogg, Chicago, IL, USA.
  • Sharma PS; Division of Cardiology, Rush University Medical Center, 1717 W. Congress Parkway, Suite 332, Kellogg, Chicago, IL, USA.
  • Nayak HM; Division of Cardiology, University of Chicago, 5758 S. Maryland Avenue M/C 9024, Chicago, IL, USA.
  • Serafini N; Division of Cardiology, Rush University Medical Center, 1717 W. Congress Parkway, Suite 332, Kellogg, Chicago, IL, USA.
  • Trohman RG; Division of Cardiology, Rush University Medical Center, 1717 W. Congress Parkway, Suite 332, Kellogg, Chicago, IL, USA.
Europace ; 21(11): 1742-1749, 2019 Nov 01.
Article en En | MEDLINE | ID: mdl-31435671
AIMS: To examine the feasibility and safety of a novel protocol for low fluoroscopy, electroanatomic mapping (EAM)-guided Cardiac resynchronization therapy with a defibrillator (CRT-D) implantation and using both EnSite NavX (St. Jude Medical, St. Paul, MN, USA) and Carto 3 (Biosense Webster, Irvine, CA, USA) mapping systems. METHODS AND RESULTS: Twenty consecutive patients underwent CRT implantation using either a conventional fluoroscopic approach (CFA) or EAM-guided lead placement with Carto 3 and EnSite NavX mapping systems. We compared fluoroscopy and procedural times, radiopaque contrast dose, change in QRS duration pre- and post-procedure, and complications in all patients. Fluoroscopy time was 86% lower in the EAM group compared to the conventional group [mean 37.2 min (CFA) vs. 5.5 min (EAM), P = 0.00003]. There was no significant difference in total procedural time [mean 183 min (CFA) vs. 161 min (EAM), P = 0.33] but radiopaque contrast usage was lower in the EAM group [mean 16 mL (CFA) vs. 4 mL (EAM), P = 0.006]. Likewise, there was no significant change in QRS duration with BiV pacing between the groups [mean -13 (CFA) vs. -25 ms (EAM), P = 0.09]. CONCLUSION: Electroanatomic mapping-guided lead placement using either Carto or ESI NavX mapping systems is a feasible alternative to conventional fluoroscopic methods for CRT-D implantation utilizing the protocol described in this study.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Mapeo del Potencial de Superficie Corporal / Imagenología Tridimensional / Terapia de Resincronización Cardíaca / Insuficiencia Cardíaca Tipo de estudio: Guideline Límite: Female / Humans / Male / Middle aged Idioma: En Revista: Europace Asunto de la revista: CARDIOLOGIA / FISIOLOGIA Año: 2019 Tipo del documento: Article País de afiliación: Estados Unidos Pais de publicación: Reino Unido

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Mapeo del Potencial de Superficie Corporal / Imagenología Tridimensional / Terapia de Resincronización Cardíaca / Insuficiencia Cardíaca Tipo de estudio: Guideline Límite: Female / Humans / Male / Middle aged Idioma: En Revista: Europace Asunto de la revista: CARDIOLOGIA / FISIOLOGIA Año: 2019 Tipo del documento: Article País de afiliación: Estados Unidos Pais de publicación: Reino Unido