Your browser doesn't support javascript.
loading
Efficient AuPd@GO-based electrochemical nanoprobe for sensitive detection of histone acetylase activity and its inhibitor.
Liu, Qiong; Yang, Linfei; She, Yuqi; Hu, Yufang.
Afiliación
  • Liu Q; Clinical Laboratory of Hunan Provincial People's Hospital, The First Affiliated Hospital of Hunan Normal University, Changsha, 410006, Hunan, China.
  • Yang L; Clinical Laboratory of Hunan Provincial People's Hospital, The First Affiliated Hospital of Hunan Normal University, Changsha, 410006, Hunan, China.
  • She Y; Blood Transfusion Department, Xiangya Hospital of Central South University, Changsha, 410008, Hunan, China. syq0922@csu.edu.cn.
  • Hu Y; Faculty of Materials Science and Chemical Engineering, Ningbo University, Ningbo, 315211, Zhejiang, China. huyufang@nbu.edu.cn.
Anal Bioanal Chem ; 411(27): 7327-7336, 2019 Nov.
Article en En | MEDLINE | ID: mdl-31520170
ABSTRACT
Histone acetylase (HAT p300), which has aroused great concern in fundamental research and clinical applications, serves as one class of significant tumor markers. In our work, a sensitive electrochemical immunoassay for testing HAT p300 based on both graphene-assisted supported AuPd nanomaterial (AuPd@GO composite) and a typical amperometric i-t technique with fast response is developed favorably. The AuPd@GO-based sensing mechanisms are distributed as follows the HAT p300 derived acetylation reaction occurs at the customized peptide-immobilized electrode; the AuPd@GO composite acts as carrier to immobilize acetyl antibody, thus constructing a sandwich-type electrochemical immunosensor via an antigen and antibody interaction; importantly, a distinct electrochemical signal could be caught due to the AuPd@GO nanomaterial with a favorable electrocatalytic property to the commercialized 3,3,5',5'-tetramethyl benzidine solution (TMB). Taking advantage of AuPd@GO composite, the established immunosensor displays a wide linear range from 1 pM to 1000 nM, and the detection limit is 0.5 pM (S/N = 3) for HAT p300. Next, the biosensor is also used to analyze the inhibitor of HAT p300 successfully, which is promising for promoting the development of electrochemical HAT-related biodetection and drug discovery. Graphical abstract A sensitive electrochemical immunoassay for testing HAT p300 based on both graphene-assisted supported AuPd nanomaterial (AuPd@GO composite) and a typical amperometric i-t technique with fast response is developed favorably.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Paladio / Inhibidores Enzimáticos / Histona Acetiltransferasas / Nanopartículas del Metal / Técnicas Electroquímicas / Oro / Grafito Tipo de estudio: Diagnostic_studies Idioma: En Revista: Anal Bioanal Chem Año: 2019 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Paladio / Inhibidores Enzimáticos / Histona Acetiltransferasas / Nanopartículas del Metal / Técnicas Electroquímicas / Oro / Grafito Tipo de estudio: Diagnostic_studies Idioma: En Revista: Anal Bioanal Chem Año: 2019 Tipo del documento: Article País de afiliación: China