Your browser doesn't support javascript.
loading
Colorimetric and electrochemical arsenate assays by exploiting the peroxidase-like activity of FeOOH nanorods.
Zhong, Xiao-Li; Wen, Shao-Hua; Wang, Yi; Luo, Yu-Xi; Li, Zhi-Mei; Liang, Ru-Ping; Zhang, Li; Qiu, Jian-Ding.
Afiliación
  • Zhong XL; College of Chemistry, Nanchang University, Nanchang, 330031, China.
  • Wen SH; College of Chemistry, Nanchang University, Nanchang, 330031, China.
  • Wang Y; College of Chemistry, Nanchang University, Nanchang, 330031, China.
  • Luo YX; College of Chemistry, Nanchang University, Nanchang, 330031, China.
  • Li ZM; College of Chemistry, Nanchang University, Nanchang, 330031, China.
  • Liang RP; College of Chemistry, Nanchang University, Nanchang, 330031, China.
  • Zhang L; College of Chemistry, Nanchang University, Nanchang, 330031, China.
  • Qiu JD; College of Chemistry, Nanchang University, Nanchang, 330031, China. jdqiu@ncu.edu.cn.
Mikrochim Acta ; 186(11): 732, 2019 10 30.
Article en En | MEDLINE | ID: mdl-31667627
ABSTRACT
The authors describe an electrochemical and an optical method for the determination of As(V) by using iron oxyhydroxide (FeOOH) nanorods that display peroxidase-mimicking activity. The nanorods catalyze the oxidation of substrate ABTS by H2O2 to form a green product with an absorption maximum at 418 nm. If, however, As(V) is electrostatically adsorbed on the nanorods, the oxidation is gradually inhibited. A colorimetric assay was worked out based on these findings. Response is linear in the 0 to 8 ppb and 8 to 200 ppb As(V) concentration range, and the detection limit is 0.1 ppb. Even higher sensitivity is achieved in an electrochemical method which is based on the excellent electrical conductivity of FeOOH nanorods. Electrochemical analysis of As(V) was achieved by first adsorbing As(V) on the nanorods. This inhibits the ABTS reduction current signal, best measured at a potential of 150 mV (vs. Ag/AgCl). The linear range extends from 0.04 to 200 ppb, and the detection limit is as low as 12 ppt. Graphical abstract Schematic representation of FeOOH nanorod-based colorimetric and electrochemical assays for arsenate (As(V)). As(V) adsorbed on FeOOH nanorods inhibits the peroxidase-mimicking activity of nanorods, and a colorimetric and electrochemical dual-signal assay was constructed to achieve sensitive determination of As(V).
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Arseniatos / Contaminantes Químicos del Agua / Compuestos Férricos / Colorimetría / Nanotubos / Técnicas Electroquímicas Idioma: En Revista: Mikrochim Acta Año: 2019 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Arseniatos / Contaminantes Químicos del Agua / Compuestos Férricos / Colorimetría / Nanotubos / Técnicas Electroquímicas Idioma: En Revista: Mikrochim Acta Año: 2019 Tipo del documento: Article País de afiliación: China