Your browser doesn't support javascript.
loading
Functionalization of PET Track-Etched Membranes by UV-Induced Graft (co)Polymerization for Detection of Heavy Metal Ions in Water.
Zdorovets, Maxim V; Korolkov, Ilya V; Yeszhanov, Arman B; Gorin, Yevgeniy G.
Afiliación
  • Zdorovets MV; L.N.Gumilyov Eurasian National University, Satpaev str., 5, Nur-Sultan 010008, Kazakhstan.
  • Korolkov IV; The Institute of Nuclear Physics, Ibragimov str., 1, Almaty 050032, Kazakhstan.
  • Yeszhanov AB; Ural Federal University, Mira str. 19, Ekaterinburg 620002, Russia.
  • Gorin YG; L.N.Gumilyov Eurasian National University, Satpaev str., 5, Nur-Sultan 010008, Kazakhstan.
Polymers (Basel) ; 11(11)2019 Nov 13.
Article en En | MEDLINE | ID: mdl-31766259
Nowadays, water quality monitoring is an essential task since environmental contamination and human exposure to heavy metals increased. Sensors that are able to detect ever lower concentrations of heavy metal ions with greater accuracy and speed are needed to effectively monitor water quality and prevent poisoning. This article shows studies of the modification of flexible track-etched membranes as the basis for the sensor with various polymers and their influence on the accuracy of detection of copper, cadmium, and lead ions in water. We report the UV-induced graft (co)polymerization of acrylic acid (AA) and 4-vinylpyridine (4-VPy) on poly(ethylene terephthalate) track-etched membrane (PET TeMs) and use them after platinum layer sputtering in square wave anodic stripping voltammetry (SW-ASV) for detection of Cu2+, Cd2+, and Pb2+. Optimal conditions leading to functionalization of the surface and retention of the pore structure were found. Modified membranes were characterized by SEM, FTIR, X-ray photoelectron spectroscopy (XPS) and colorimetric analysis. The dependence of the modification method on the sensitivity of the sensor was shown. Membrane modified with polyacrylic acid (PET TeMs-g-PAA), poly(4-vinylpyridine) (PET TeMs-g-P4VPy), and their copolymer (PET TeMs-g-P4VPy/PAA) with average grafting yield of 3% have been found to be sensitive to µg/L concentration of copper, lead, and cadmium ions. Limits of detection (LOD) for sensors based on PET TeMs-g-PAA are 2.22, 1.05, and 2.53 µg/L for Cu2+, Pb2+, and Cd2+, respectively. LODs for sensors based on PET TeMs-g-P4VPy are 5.23 µg/L (Cu2+), 1.78 µg/L (Pb2+), and 3.64 µg/L (Cd2+) µg/L. PET TeMs-g-P4VPy/PAA electrodes are found to be sensitive with LODs of 0.74 µg/L(Cu2+), 1.13 µg/L (Pb2+), and 2.07 µg/L(Cd2+). Thus, it was shown that the modification of membranes by copolymers with carboxylic and amino groups leads to more accurate detection of heavy metal ions, associated with the formation of more stable complexes.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Diagnostic_studies Idioma: En Revista: Polymers (Basel) Año: 2019 Tipo del documento: Article País de afiliación: Kazajstán Pais de publicación: Suiza

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Diagnostic_studies Idioma: En Revista: Polymers (Basel) Año: 2019 Tipo del documento: Article País de afiliación: Kazajstán Pais de publicación: Suiza