Your browser doesn't support javascript.
loading
Effect of Using a Cardiac Catheterization Table-Stabilizing Stick on the Quality of Cardiopulmonary Resuscitation in the Cardiac Catheterization Laboratory: A Simulation-Based Study.
Yamada, Tsuyoshi; Ito, Morihiro; Urai, Hisako; Ueda, Yumiko; Maki, Hiroaki; Baba, Reizo.
Afiliación
  • Yamada T; Graduate School of Life and Health Sciences, Chubu University, Aichi, Japan.
  • Ito M; Graduate School of Life and Health Sciences, Chubu University, Aichi, Japan.
  • Urai H; Department of Biomedical Sciences, College of Life and Health Science, Chubu University, Aichi, Japan.
  • Ueda Y; Department of Lifelong Sports and Health Sciences, College of Life and Health Science, Chubu University, Aichi, Japan.
  • Maki H; Department of Lifelong Sports and Health Sciences, College of Life and Health Science, Chubu University, Aichi, Japan.
  • Baba R; Faculty of Nursing, Gifu Shotoku Gakuen University, Gifu, Japan.
J Interv Cardiol ; 2019: 6303978, 2019.
Article en En | MEDLINE | ID: mdl-31772537
ABSTRACT
Rapid defibrillation and high-quality cardiopulmonary resuscitation (CPR) are necessary for patients with cardiopulmonary arrest, one of the most serious and frequently encountered complications in cardiac catheterization laboratories. However, when the catheterization table is withdrawn from its neutral position for fluoroscopy, it is unstable and unsuitable for resuscitation because of its cantilever structure. To stabilize the table in its withdrawn position, the use of a table-stabilizing stick might improve CPR quality. To investigate the effect of using a cardiac catheterization table-stabilizing stick on CPR quality, a CPR simulation mannequin was placed on a cardiac catheterization table that was withdrawn from the C-arm of the X-ray machine. CPR quality was assessed with or without the use of a table-stabilizing stick under the table. The CPR quality assessment (Q-CPR) scores were 79.6 ± 11.4% using the table-stabilizing stick and 47.7 ± 30.3% without the use of the stick device (p = 0.02). In this simulation-based study, the use of a table-stabilizing stick in a cardiac catheterization table withdrawn from the C-arm of the X-ray machine improved the quality of CPR.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Cateterismo Cardíaco / Reanimación Cardiopulmonar / Falla de Equipo / Mesas de Operaciones / Paro Cardíaco Límite: Humans Idioma: En Revista: J Interv Cardiol Asunto de la revista: CARDIOLOGIA Año: 2019 Tipo del documento: Article País de afiliación: Japón

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Cateterismo Cardíaco / Reanimación Cardiopulmonar / Falla de Equipo / Mesas de Operaciones / Paro Cardíaco Límite: Humans Idioma: En Revista: J Interv Cardiol Asunto de la revista: CARDIOLOGIA Año: 2019 Tipo del documento: Article País de afiliación: Japón
...