Modelling of the focal spot intensity distribution and the off-focal spot radiation in kilovoltage x-ray tubes for imaging.
van der Heyden, Brent; Fonseca, Gabriel Paiva; Podesta, Mark; Messner, Ivan; Reisz, Niklas; Vaniqui, Ana; Deutschmann, Heinz; Steininger, Phil; Verhaegen, Frank.
Afiliación
  • van der Heyden B; Department of Radiation Oncology (MAASTRO), GROW-School for Oncology and Developmental Biology, Maastricht University Medical Centre, Maastricht, The Netherlands.
Phys Med Biol ; 65(2): 025002, 2020 01 17.
Article en En | MEDLINE | ID: mdl-31835265
X-ray tubes for medical applications typically generate x-rays by accelerating electrons, emitted from a cathode, with an interelectrode electric field, towards an anode target. X-rays are not emitted from one point, but from an irregularly shaped area on the anode, the focal spot. Focal spot intensity distributions and off-focal radiation negatively affect the imaging spatial resolution and broadens the beam penumbra. In this study, a Monte Carlo simulation model of an x-ray tube was developed to evaluate the spectral and spatial characteristics of off-focal radiation for multiple photon energies. Slit camera measurements were used to determine the horizontal and vertical intensity profiles of the small and the large focal spot of a diagnostic x-ray tube. First, electron beamlet weighting factors were obtained via an iterative optimization method to represent both focal spot sizes. These weighting factors were then used to extract off-focal spot radiation characteristics for the small and large focal spot sizes at 80, 100, and 120 kV. Finally, 120 kV simulations of a steel sphere (d = 4 mm) were performed to investigate image blurring with a point source, the small focal spot, and the large focal spot. The magnitude of off-focal radiation strongly depends on the anode size and the electric field coverage, and only minimally on the tube potential and the primary focal spot size. In conclusion, an x-ray tube Monte Carlo simulation model was developed to simulate focal spot intensity distributions and to evaluate off-focal radiation characteristics at several energies. This model can be further employed to investigate focal spot correction methods and to improve cone-beam CT image quality.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Radiografía / Método de Montecarlo / Fotones Tipo de estudio: Diagnostic_studies / Health_economic_evaluation / Prognostic_studies Idioma: En Revista: Phys Med Biol Año: 2020 Tipo del documento: Article País de afiliación: Países Bajos Pais de publicación: Reino Unido

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Radiografía / Método de Montecarlo / Fotones Tipo de estudio: Diagnostic_studies / Health_economic_evaluation / Prognostic_studies Idioma: En Revista: Phys Med Biol Año: 2020 Tipo del documento: Article País de afiliación: Países Bajos Pais de publicación: Reino Unido