Your browser doesn't support javascript.
loading
Quantitation of MR relaxation effects of iron oxide particles in liver and spleen.
Majumdar, S; Zoghbi, S; Pope, C F; Gore, J C.
Afiliación
  • Majumdar S; Department of Diagnostic Radiology, Yale School of Medicine, New Haven, CT 06510.
Radiology ; 169(3): 653-8, 1988 Dec.
Article en En | MEDLINE | ID: mdl-3186986
ABSTRACT
The relaxation effects and organ distribution of superparamagnetic iron oxide particles for magnetic resonance imaging were measured in rats. T1 and T2 were measured for excised organs, and tissue iron levels were quantified with radiolabeling. Approximately 70% of the injected dose is present in the liver and 10% in the spleen 1 hour after injection. At 20 MHz, the doses required to reduce liver and spleen T2 to half the normal value, as measured with a Carr-Purcell-Meiboom-Gill sequence, were, respectively, 420 and 830 mumol iron injected per kilogram of rat. The transverse relaxation rates increase linearly with injected dose and showed no evidence of saturation. These results suggest that this material is less effective than previously suggested.
Asunto(s)
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Bazo / Imagen por Resonancia Magnética / Compuestos Férricos / Medios de Contraste / Hígado Límite: Animals Idioma: En Revista: Radiology Año: 1988 Tipo del documento: Article