[Multiple simultaneous stratigraphy. Results with a 5-plane system for pediatric use]. / Stratigrafia multipla simultanea. Risultati di un sistema a 5 strati per uso pediatrico.
Iannaccone, G; Capocaccia, P; Boi, A; Calì, M; Del Chierico, G; Morelli, C; Ricci, L.
Afiliación
  • Iannaccone G; Servizio Autonomo di Radiologia Pediatrica, Università La Sapienza, Roma.
Radiol Med ; 76(4): 333-6, 1988 Oct.
Article en It | MEDLINE | ID: mdl-3187090
ABSTRACT
The authors report the results of a five-layer simultaneous multisection tomographic technique to be used in pediatric radiology, based on an appropriately selected series of Trimax rare-earth intensifying screens arranged in progressive speed order. The technique has been so far employed with excellent results in 100 children, especially during IVP, when X-ray examination is very frequently disturbed by ileocolic gas. The many advantages of the technique are emphasized a) all sections are perfectly parallel and simultaneous, in the same respiratory phase and body position; b) film density is practically identical in all sections; c) there is considerable saving in time, machine consumption, and radiation dose.
Asunto(s)
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Tomografía por Rayos X Límite: Child / Humans Idioma: It Revista: Radiol Med Año: 1988 Tipo del documento: Article