Your browser doesn't support javascript.
loading
[The Application Value of One-stop CT Myocardial Perfusion Imaging in the Evaluation of Patients with Severe Coronary Artery Stenosis].
Liu, Ke-Ling; Peng, Wan-Lin; Xu, Xu; Luo, Ting; Zhang, Jin-Ge; Hu, Si-Xian; Diao, Kai-Yue; Li, Lei; Xia, Chun-Chao; Li, Zhen-Lin.
Afiliación
  • Liu KL; Department of Radiology, West China Hospital, Sichuan University, Chengdu 610041, China.
  • Peng WL; Department of Radiology, West China Hospital, Sichuan University, Chengdu 610041, China.
  • Xu X; Department of Radiology, West China Hospital, Sichuan University, Chengdu 610041, China.
  • Luo T; Department of Radiology, West China Hospital, Sichuan University, Chengdu 610041, China.
  • Zhang JG; Department of Radiology, West China Hospital, Sichuan University, Chengdu 610041, China.
  • Hu SX; Department of Radiology, West China Hospital, Sichuan University, Chengdu 610041, China.
  • Diao KY; Department of Radiology, West China Hospital, Sichuan University, Chengdu 610041, China.
  • Li L; Department of Radiology, West China Hospital, Sichuan University, Chengdu 610041, China.
  • Xia CC; Department of Radiology, West China Hospital, Sichuan University, Chengdu 610041, China.
  • Li ZL; Department of Radiology, West China Hospital, Sichuan University, Chengdu 610041, China.
Sichuan Da Xue Xue Bao Yi Xue Ban ; 50(6): 878-883, 2019 Dec.
Article en Zh | MEDLINE | ID: mdl-31880121
ABSTRACT
ObstractPurpose "One-stop" CT myocardial perfusion imaging (CT-MPI) was compared with cardiac magnetic resonance(CMR) to investigate its application value in evaluating patients with severe coronary artery stenosis.MethodsFifty patients with coronary artery stenosis≥90% of at least one major coronary arteries comfirmed by coronary angiography (CAG) in the department of cardiology in our hospital, who referred for coronary artery stent implantation were prospectively enrolled. All the patients underwent "One-stop" CT-MPI within a week before surgery, among which 22 patients underwent CMR examination simultaneously. The postprocessing software Ziostation2 was used to obatin and compare the perfusion parameters of patients with normal and perfusion defect myocardium, including blood flow (BF), blood volume (BV), peak time (TTP), and mean transit time (MTT). Pearson correlation analysis was used to compare the correlation of relative perfusion parameters (defect/normal myocardium) between CT and CMR. Bland-Altman analysis was used to analyze the consistency between CT and CMR in left ventricular (LV) function parameters measurements.ResultsCompared with normal myocardium, BV and BF of perfusion defect myocardium were significantly decreased, while MTT and TTP were significantly prolonged (all P < 0.05). The rBV, rBF, rMTT and rTTP were medium to high positive correlated between CT and CMR (r=0.685, 0.641, 0.871, 0.733, respectively, all P < 0.05). Bland-Altman analysis showed that 95% (21/22) points were within the 95% limits of agreement (LoA), suggesting the LV function parameters measurements between two methods were highly consistent.Conclusion"One-stop" CT-MPI can simultaneously obtain the information about coronary anatomy, myocardial perfusion and LV function. It is of great value in the evaluation of patients with severe coronary artery stenosis, with shorter scan time and less contraindications compared with CMR.
Asunto(s)
Palabras clave
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Enfermedad de la Arteria Coronaria / Estenosis Coronaria / Imagen de Perfusión Miocárdica Límite: Humans Idioma: Zh Revista: Sichuan Da Xue Xue Bao Yi Xue Ban Año: 2019 Tipo del documento: Article País de afiliación: China
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Enfermedad de la Arteria Coronaria / Estenosis Coronaria / Imagen de Perfusión Miocárdica Límite: Humans Idioma: Zh Revista: Sichuan Da Xue Xue Bao Yi Xue Ban Año: 2019 Tipo del documento: Article País de afiliación: China