Development of a Knee Joint CT-FEM Model in Load Response of the Stance Phase During Walking Using Muscle Exertion, Motion Analysis, and Ground Reaction Force Data.
Watanabe, Kunihiro; Mutsuzaki, Hirotaka; Fukaya, Takashi; Aoyama, Toshiyuki; Nakajima, Syuichi; Sekine, Norio; Mori, Koichi.
Afiliación
  • Watanabe K; Department of Radiology, Saitama Prefecture Saiseikai Kurihashi Hospital, Kuki, Saitama 349-1105, Japan.
  • Mutsuzaki H; Department of Radiological Sciences, Graduate School of Human Health Sciences, Tokyo Metropolitan University, Arakawa, Tokyo 116-8551, Japan.
  • Fukaya T; Center for Medical Sciences, Ibaraki Prefectural University of Health Sciences, Ami, Ibaraki 300-0394, Japan.
  • Aoyama T; Department of Orthopaedic Surgery, Ibaraki Prefectural University of Health Sciences Hospital, Ami, Ibaraki 300-0331, Japan.
  • Nakajima S; Department of Physical Therapy, Faculty of Health Sciences, Tsukuba International University, Tsuchiura, Ibaraki 300-0051, Japan.
  • Sekine N; Department of Physical Therapy, Ibaraki Prefectural University of Health Sciences, Ami, Ibaraki 300-0394, Japan.
  • Mori K; Department of Radiological Sciences, Ibaraki Prefectural University of Health Sciences, Ami, Ibaraki 300-0394, Japan.
Medicina (Kaunas) ; 56(2)2020 Jan 29.
Article en En | MEDLINE | ID: mdl-32013100
ABSTRACT
Background and

objectives:

There are no reports on articular stress distribution during walking based on any computed tomography (CT)-finite element model (CT-FEM). This study aimed to develop a calculation model of the load response (LR) phase, the most burdensome phase on the knee, during walking using the finite element method of quantitative CT images. Materials and

Methods:

The right knee of a 43-year-old man who had no history of osteoarthritis or surgeries of the knee was examined. An image of the knee was obtained using CT and the extension position image was converted to the flexion angle image in the LR phase. The bone was composed of heterogeneous materials. The ligaments were made of truss elements; therefore, they do not generate strain during expansion or contraction and do not affect the reaction force or pressure. The construction of the knee joint included material properties of the ligament, cartilage, and meniscus. The extensor and flexor muscles were calculated and set as the muscle exercise tension around the knee joint. Ground reaction force was vertically applied to suppress the rotation of the knee, and the thigh was restrained.

Results:

An FEM was constructed using a motion analyzer, floor reaction force meter, and muscle tractive force calculation. In a normal knee, the equivalent stress and joint contact reaction force in the LR phase were distributed over a wide area on the inner upper surface of the femur and tibia.

Conclusions:

We developed a calculation model in the LR phase of the knee joint during walking using a CT-FEM. Methods to evaluate the heteromorphic risk, mechanisms of transformation, prevention of knee osteoarthritis, and treatment may be developed using this model.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Caminata / Soporte de Peso / Artroplastia de Reemplazo / Articulación de la Rodilla Tipo de estudio: Prognostic_studies Límite: Adult / Humans / Male Idioma: En Revista: Medicina (Kaunas) Asunto de la revista: MEDICINA Año: 2020 Tipo del documento: Article País de afiliación: Japón

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Caminata / Soporte de Peso / Artroplastia de Reemplazo / Articulación de la Rodilla Tipo de estudio: Prognostic_studies Límite: Adult / Humans / Male Idioma: En Revista: Medicina (Kaunas) Asunto de la revista: MEDICINA Año: 2020 Tipo del documento: Article País de afiliación: Japón