Your browser doesn't support javascript.
loading
Sensitive detection of influenza a virus based on a CdSe/CdS/ZnS quantum dot-linked rapid fluorescent immunochromatographic test.
Nguyen, Anh Viet Thi; Dao, Tung Duy; Trinh, Tien Thi Thuy; Choi, Du-Young; Yu, Seung-Taek; Park, Hyun; Yeo, Seon-Ju.
Afiliación
  • Nguyen AVT; Zoonosis Research Center, Department of Infection Biology, School of Medicine, Wonkwang University, 460, Iksan-daero, Iksan, 54538, Republic of Korea.
  • Dao TD; Zoonosis Research Center, Department of Infection Biology, School of Medicine, Wonkwang University, 460, Iksan-daero, Iksan, 54538, Republic of Korea.
  • Trinh TTT; Zoonosis Research Center, Department of Infection Biology, School of Medicine, Wonkwang University, 460, Iksan-daero, Iksan, 54538, Republic of Korea.
  • Choi DY; Department of Pediatrics, School of Medicine, Wonkwang University, 460, Iksan-daero, Iksan, 54538, Republic of Korea.
  • Yu ST; Department of Pediatrics, School of Medicine, Wonkwang University, 460, Iksan-daero, Iksan, 54538, Republic of Korea.
  • Park H; Zoonosis Research Center, Department of Infection Biology, School of Medicine, Wonkwang University, 460, Iksan-daero, Iksan, 54538, Republic of Korea.
  • Yeo SJ; Zoonosis Research Center, Department of Infection Biology, School of Medicine, Wonkwang University, 460, Iksan-daero, Iksan, 54538, Republic of Korea. Electronic address: yeosj@wku.ac.kr.
Biosens Bioelectron ; 155: 112090, 2020 May 01.
Article en En | MEDLINE | ID: mdl-32090866
ABSTRACT
Prevention is the most effective management strategy for influenza A infection in humans. In this study, we developed a CdSe/CdS/ZnS quantum dot (QD) fluorescent dye for rapid and sensitive detection of two common subtypes (H1N1 and H3N2) of influenza A virus, and examined its utility. CdSe/CdS/ZnS QD was conjugated with antibody (Ab) after conjugation with latex, making QD conjugate of QD + Latex + Ab. A stable photoluminescence of QD conjugate and advantage of CdSe/CdS/ZnS QD used was characterized in this study. The performance of a rapid fluorescent immunochromatographic test (FICT) employing QD conjugate (QD-FICT) in detecting influenza A/H1N1 was 8-fold and 64-fold higher than that of a europium nanoparticle-based FICT and a rapid diagnostic test (RDT; Standard Diagnostics BIOLINE Influenza A/B), respectively. For influenza A/H3N2, QD-FICT showed 8-fold and 128-fold higher performance than europium nanoparticle-based FICT and RDT, respectively. In clinical evaluations, QD-FICT showed 93.75% clinical sensitivity [45/48; 95% confidence interval (95% CI) 82.80-98.69], 100% clinical specificity (117/117; 95% CI 96.90-100.00), and strong correlation (kappa; 0.98) with rRT-PCR (20 ≤ Ct ≤ 40). Europium nanoparticle-linked FICT showed 79.17% clinical sensitivity (38/48; 95% CI 65.01-89.53) and 100% clinical specificity (117/117; 95% CI 96.90-100.00), whereas RDT showed 77.08% sensitivity (37/48; 95% CI 62.69-87.97), 100% specificity (117/117; 95% CI 96.90-100.00), and reasonably good correlation with rRT-PCR (kappa; 0.93). Water-soluble QDs can therefore be used as an effective material for developing fluorescent diagnostic systems for rapid detection of human influenza A virus in clinical specimens.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Virus de la Influenza A / Sulfuros / Inmunoensayo / Compuestos de Zinc / Compuestos de Selenio / Compuestos de Cadmio / Puntos Cuánticos / Gripe Humana Tipo de estudio: Diagnostic_studies Límite: Humans Idioma: En Revista: Biosens Bioelectron Asunto de la revista: BIOTECNOLOGIA Año: 2020 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Virus de la Influenza A / Sulfuros / Inmunoensayo / Compuestos de Zinc / Compuestos de Selenio / Compuestos de Cadmio / Puntos Cuánticos / Gripe Humana Tipo de estudio: Diagnostic_studies Límite: Humans Idioma: En Revista: Biosens Bioelectron Asunto de la revista: BIOTECNOLOGIA Año: 2020 Tipo del documento: Article
...