Your browser doesn't support javascript.
loading
Nonlinearly Frequency-Adaptive, Self-Powered, Proton-Driven Somatosensor Inspired by a Human Mechanoreceptor.
Chun, Kyoung-Yong; Son, Young Jun; Seo, Seunghwan; Lee, Ho Jung; Han, Chang-Soo.
Afiliación
  • Chun KY; School of Mechanical Engineering, College of Engineering, Korea University, Anam-Dong, Seongbuk-Gu, Seoul 136-713, Republic of Korea.
  • Son YJ; School of Mechanical Engineering, College of Engineering, Korea University, Anam-Dong, Seongbuk-Gu, Seoul 136-713, Republic of Korea.
  • Seo S; School of Mechanical Engineering, College of Engineering, Korea University, Anam-Dong, Seongbuk-Gu, Seoul 136-713, Republic of Korea.
  • Lee HJ; School of Mechanical Engineering, College of Engineering, Korea University, Anam-Dong, Seongbuk-Gu, Seoul 136-713, Republic of Korea.
  • Han CS; School of Mechanical Engineering, College of Engineering, Korea University, Anam-Dong, Seongbuk-Gu, Seoul 136-713, Republic of Korea.
ACS Sens ; 5(3): 845-852, 2020 03 27.
Article en En | MEDLINE | ID: mdl-32096629
ABSTRACT
In the human skin, it has been well known that several mechanoreceptors uniquely sense external stimuli with specific frequencies and magnitudes. With regard to sensitivity, the output response shows nonlinearity depending on the frequency magnitude of the stimulus. We demonstrate a self-powered proton-driven solid-state somatosensor, which mimics a unique nonlinear response and intensity behavior of human mechanoreceptors. For this, a solid-state sensor is fabricated by combining a piezoelectric film and a proton generation device. The proton injection electrode and the Nafion layer conjugated with sulfonated graphene oxide are used for proton generation and transport. Two types of nonlinear signals from the sensor are similar to the Merkel/Ruffini (low deviation of threshold intensity), and in contrast, the behavior of Pacinian/Meissner (high deviation of threshold intensity) is simultaneously shown. The region of the most responsive frequency is also discriminated according to proton conduction. Moreover, it is asserted that unique signal patterns are obtained from the stimuli of various frequencies, such as respiration, radial artery pulse, and neck vibration, which naturally occur in the human body.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Protones / Mecanorreceptores Límite: Humans Idioma: En Revista: ACS Sens Año: 2020 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Protones / Mecanorreceptores Límite: Humans Idioma: En Revista: ACS Sens Año: 2020 Tipo del documento: Article