Your browser doesn't support javascript.
loading
Initial experience in combined ultra-mini percutaneous nephrolithotomy with the use of 120-W laser and the anti-retropulsion "Moses effect": the future of percutaneous nephrolithotomy?
Leotsakos, Ioannis; Katafigiotis, Ioannis; Lorber, Amitay; Sfoungaristos, Stavros; Sabler, Itay M; Yutkin, Vladimir; Gofrit, Ofer N; Duvdevani, Mordechai.
Afiliación
  • Leotsakos I; Department of Urology, Hadassah Hebrew University Medical Center, Jerusalem, Israel. j_leot@yahoo.gr.
  • Katafigiotis I; Department of Urology, Hadassah Hebrew University Medical Center, Jerusalem, Israel.
  • Lorber A; Department of Urology, Hadassah Hebrew University Medical Center, Jerusalem, Israel.
  • Sfoungaristos S; Department of Urology, Hadassah Hebrew University Medical Center, Jerusalem, Israel.
  • Sabler IM; Department of Urology, Hadassah Hebrew University Medical Center, Jerusalem, Israel.
  • Yutkin V; Department of Urology, Hadassah Hebrew University Medical Center, Jerusalem, Israel.
  • Gofrit ON; Department of Urology, Hadassah Hebrew University Medical Center, Jerusalem, Israel.
  • Duvdevani M; Department of Urology, Hadassah Hebrew University Medical Center, Jerusalem, Israel.
Lasers Med Sci ; 35(9): 1961-1966, 2020 Dec.
Article en En | MEDLINE | ID: mdl-32112249
ABSTRACT
The purpose is to present our preliminary results where ultra-mini PCNL (UMPCNL) with the new 120-watt laser with the anti-retropulsion (Lumenis® MOSES Pulse™120H Holmium YAG laser) was used for the first time to our knowledge. Twelve patients underwent ultra-mini PCNL in prone position under general anesthesia using a 12-F nephroscope with a 14-F Access sheath in our tertiary center. The fragmentation was performed with a 500 µm laser fiber using the 120-watt Lumenis® MOSES Pulse™120H Holmium YAG laser). Efficacy was considered in terms of stone-free rates (SFR), complication rate, duration of the operation, and hospital stay. Our SFR was 91.6% with 11 patients out of 12 being completely free of any residual stone. The duration of the operation was 86.4 ± 36.8 (40-165) min, whereas the mean laser time (real stone fragmentation laser time) was 755.7 ± 954.7(241-3425) sec. The total laser energy used was 39.7 ± 52 KJoules (11.3-182). The fluoroscopy time and radiation doses were 358.5 ± 180.4 (154-750) sec and 64.7 ± 41.2 (14.7-159.0) mGy, respectively. The mean reduction in levels of hemoglobin postoperatively was 0.6 ± 0.3 (0.1-0.9) g/dL, and no complications were observed. The combination of UMPCNL with the new 120-watt laser and the unique anti-retropulsion technology (Lumenis® MOSES Pulse™120H Holmium YAG laser) delivered very promising results and it could be the future of PCNL.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Láseres de Estado Sólido / Nefrolitotomía Percutánea Límite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Lasers Med Sci Asunto de la revista: BIOTECNOLOGIA / RADIOLOGIA Año: 2020 Tipo del documento: Article País de afiliación: Israel

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Láseres de Estado Sólido / Nefrolitotomía Percutánea Límite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Lasers Med Sci Asunto de la revista: BIOTECNOLOGIA / RADIOLOGIA Año: 2020 Tipo del documento: Article País de afiliación: Israel
...