Your browser doesn't support javascript.
loading
Measurement Properties of the Multiple Errands Test: A Systematic Review.
Rotenberg, Shlomit; Ruthralingam, Moira; Hnatiw, Brett; Neufeld, Kimberley; Yuzwa, Kirstin E; Arbel, Ifah; Dawson, Deirdre R.
Afiliación
  • Rotenberg S; Rotman Research Institute, Baycrest, Toronto, Ontario, Canada. Electronic address: srotenberg@research.baycrest.org.
  • Ruthralingam M; Department of Occupational Science & Occupational Therapy, University of Toronto, Toronto, Ontario, Canada.
  • Hnatiw B; Department of Occupational Science & Occupational Therapy, University of Toronto, Toronto, Ontario, Canada.
  • Neufeld K; Department of Occupational Science & Occupational Therapy, University of Toronto, Toronto, Ontario, Canada.
  • Yuzwa KE; Rotman Research Institute, Baycrest, Toronto, Ontario, Canada.
  • Arbel I; Department of Occupational Science & Occupational Therapy, University of Toronto, Toronto, Ontario, Canada.
  • Dawson DR; Rotman Research Institute, Baycrest, Toronto, Ontario, Canada; Department of Occupational Science & Occupational Therapy, University of Toronto, Toronto, Ontario, Canada.
Arch Phys Med Rehabil ; 101(9): 1628-1642, 2020 09.
Article en En | MEDLINE | ID: mdl-32113973
ABSTRACT

OBJECTIVE:

To systematically review, summarize, and evaluate published evidence on measurement properties of real-world versions of the Multiple Errands Test (MET) following Consensus-based Standards for the Selection of Health Measurement Instruments guidelines. DATA SOURCES Four databases were searched in May 2019 using multiple variants of the name of the MET from 1991 onward following the publication of the original MET. STUDY SELECTION We included peer-reviewed original research articles in English that provided data on measurement properties (reliability, validity, and responsiveness to change) on real-world versions of the MET in any clinical population. DATA EXTRACTION Data on the MET characteristics, study population, and evidence for each measurement property were extracted using predefined criteria. The review team critically appraised the methodological quality and rated the results from each study as sufficient (+), insufficient (-), or indeterminate (?). DATA

SUMMARY:

Data on each measurement property were pooled. Pooled results were rated as sufficient (+), insufficient (-), mixed (±), or indeterminate (?). The overall quality of evidence per measurement property was graded based on risk of bias, sample size, and consistency of results. The overall evidence for each measurement property was determined as high, moderate, low, or very low.

RESULTS:

We found 33 studies that provided data on measurement properties of real-world versions of the MET. Pooled results revealed high-quality evidence for interrater reliability and moderate-quality evidence for known-group validity. Limited support for other kinds of reliability and validity was found.

CONCLUSIONS:

This review suggests the MET should be used cautiously. Reasons for the limited psychometric support are discussed, the value of generic forms of the MET that do not require site specific adaptations is noted, and areas for further psychometric work are highlighted.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Función Ejecutiva / Pruebas Neuropsicológicas Tipo de estudio: Guideline / Systematic_reviews Límite: Humans Idioma: En Revista: Arch Phys Med Rehabil Año: 2020 Tipo del documento: Article Pais de publicación: EEUU / ESTADOS UNIDOS / ESTADOS UNIDOS DA AMERICA / EUA / UNITED STATES / UNITED STATES OF AMERICA / US / USA

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Función Ejecutiva / Pruebas Neuropsicológicas Tipo de estudio: Guideline / Systematic_reviews Límite: Humans Idioma: En Revista: Arch Phys Med Rehabil Año: 2020 Tipo del documento: Article Pais de publicación: EEUU / ESTADOS UNIDOS / ESTADOS UNIDOS DA AMERICA / EUA / UNITED STATES / UNITED STATES OF AMERICA / US / USA