Stepwise Assembly of Turn-on Fluorescence Sensors in Multicomponent Metal-Organic Frameworks for in Vitro Cyanide Detection.
Li, Jialuo; Yuan, Shuai; Qin, Jun-Sheng; Pang, Jiandong; Zhang, Peng; Zhang, Yingmu; Huang, Yanyan; Drake, Hannah F; Liu, Wenshe R; Zhou, Hong-Cai.
Afiliación
  • Li J; Department of Chemistry, Texas A&M University, College Station, TX, 77843-3255, USA.
  • Yuan S; Department of Chemistry, Texas A&M University, College Station, TX, 77843-3255, USA.
  • Qin JS; Department of Chemistry, Texas A&M University, College Station, TX, 77843-3255, USA.
  • Pang J; Department of Chemistry, Texas A&M University, College Station, TX, 77843-3255, USA.
  • Zhang P; Department of Chemistry, Texas A&M University, College Station, TX, 77843-3255, USA.
  • Zhang Y; Department of Chemistry, Texas A&M University, College Station, TX, 77843-3255, USA.
  • Huang Y; Department of Chemistry, Texas A&M University, College Station, TX, 77843-3255, USA.
  • Drake HF; Department of Chemistry, Texas A&M University, College Station, TX, 77843-3255, USA.
  • Liu WR; Department of Chemistry, Texas A&M University, College Station, TX, 77843-3255, USA.
  • Zhou HC; Department of Chemistry, Texas A&M University, College Station, TX, 77843-3255, USA.
Angew Chem Int Ed Engl ; 59(24): 9319-9323, 2020 06 08.
Article en En | MEDLINE | ID: mdl-32174003
ABSTRACT
The controlled synthesis of multicomponent metal-organic frameworks (MOFs) allows for the precise placement of multiple cooperative functional groups within a framework, leading to emergent synergistic effects. Herein, we demonstrate that turn-on fluorescence sensors can be assembled by combining a fluorophore and a recognition moiety within a complex cavity of a multicomponent MOF. An anthracene-based fluorescent linker and a hemicyanine-containing CN- -responsive linker were sequentially installed into the lattice of PCN-700. The selective binding of CN- to hemicyanine inhibited the energy transfer between the two moieties, resulting in a fluorescence turn-on effect. Taking advantage of the high tunability of the MOF platform, the ratio between anthracene and the hemicyanine moiety could be fine-tuned in order to maximize the sensitivity of the overall framework. The optimized MOF-sensor had a CN- -detection limit of 0.05 µm, which is much lower than traditional CN- fluorescent sensors (about 0.2 µm).