Your browser doesn't support javascript.
loading
Fast screening method for molecular recognition of islet amyloid polypeptide from whole blood samples collected from diabetic patients with disposable stochastic sensors obtained by nanolayer, and nanolayer by nanolayer deposition using cold plasma.
Stefan-van Staden, Raluca-Ioana; Popa-Tudor, Ioana; Badulescu, Marius; Anghel, Alexandru.
Afiliación
  • Stefan-van Staden RI; Laboratory of Electrochemistry and PATLAB, National Institute of Research for Electrochemistry and Condensed Matter, 202 Splaiul Independentei Str., 060021, Bucharest-6, Romania. ralucavanstaden@gmail.com.
  • Popa-Tudor I; Laboratory of Electrochemistry and PATLAB, National Institute of Research for Electrochemistry and Condensed Matter, 202 Splaiul Independentei Str., 060021, Bucharest-6, Romania.
  • Badulescu M; National Institute for Laser, Plasma & Radiation Physics, 409 Str Atomistilor, 077125, Magurele, Romania. marius.badulescu@inflpr.ro.
  • Anghel A; National Institute for Laser, Plasma & Radiation Physics, 409 Str Atomistilor, 077125, Magurele, Romania.
Anal Bioanal Chem ; 412(17): 4135-4141, 2020 Jul.
Article en En | MEDLINE | ID: mdl-32296903
ABSTRACT
Nanolayer and nanolayer by nanolayer deposition of nanofilms of Ag and C using cold plasma in sequences (Ag, Ag-C, Ag-Ag-C), on porous paper, were used to design three disposable stochastic sensors for the assay of amyloid polypeptide from whole blood. The nanofilms were modified with α-cyclodextrin. The test developed using the nanofilm-based disposable stochastic sensors is used for early detection of diabetes. The wider linear concentration range (1.00 × 10-6-1.00 ng mL-1) and the lower limit of quantification (1.00 × 10-6ng mL-1) were obtained using the disposable stochastic sensors based on Ag-C and Ag-Ag-C, while the highest sensitivity (3.19 × 104 s-1/µg mL-1) was recorded using the disposable stochastic sensor based on Ag-Ag-C. The screening methods were fully validated using whole blood samples from confirmed patients, when the recovery of the islet amyloid polypeptide was higher than 98.00%. Graphical abstract.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Nanoestructuras / Diabetes Mellitus Tipo 1 / Diabetes Mellitus Tipo 2 / Técnicas Electroquímicas / Polipéptido Amiloide de los Islotes Pancreáticos Tipo de estudio: Diagnostic_studies / Screening_studies Límite: Humans Idioma: En Revista: Anal Bioanal Chem Año: 2020 Tipo del documento: Article País de afiliación: Rumanía

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Nanoestructuras / Diabetes Mellitus Tipo 1 / Diabetes Mellitus Tipo 2 / Técnicas Electroquímicas / Polipéptido Amiloide de los Islotes Pancreáticos Tipo de estudio: Diagnostic_studies / Screening_studies Límite: Humans Idioma: En Revista: Anal Bioanal Chem Año: 2020 Tipo del documento: Article País de afiliación: Rumanía