Your browser doesn't support javascript.
loading
Outcome of a 980-nm diode laser coagulation in women with radiation-induced hemorrhagic cystitis: a single-center retrospective study.
Zhang, Ning; Yao, Dong-Wei; Liu, Xue-Jun; Sun, Yi; Song, Qun.
Afiliación
  • Zhang N; Department of Medical Nursing, Lianyungang Higher Vocational College of Traditional Chinese Medicine, Lianyungang, Jiangsu, China.
  • Yao DW; Department of Urology, The Second People's Hospital of Lianyungang, 161 Xingfu Road, Lianyungang, 222023, Jiangsu, China. yaodongwei0916@163.com.
  • Liu XJ; Department of Urology, The Second People's Hospital of Lianyungang, 161 Xingfu Road, Lianyungang, 222023, Jiangsu, China.
  • Sun Y; Department of Radiology, The Second People's Hospital of Lianyungang, Lianyungang, Jiangsu, China.
  • Song Q; Department of Urology, The Second People's Hospital of Lianyungang, 161 Xingfu Road, Lianyungang, 222023, Jiangsu, China.
Lasers Med Sci ; 36(1): 67-73, 2021 Feb.
Article en En | MEDLINE | ID: mdl-32304002
ABSTRACT
The purpose of this study was to evaluate the efficacy of a 980-nm diode laser coagulation in women with radiation-induced hemorrhagic cystitis (RHC). We conducted a retrospective study of 21 RHC patients treated with a 980-nm diode laser between July 2014 and December 2017 at our institution. Data was collected with regard to age, sex, lower urinary tract symptoms, use of transfusions, a drop in hemoglobin levels, indication of radiotherapy, median time between radiation therapy and presentation, previous treatments, operative time, mean energy used, number of coagulated areas, catheterization time, discharge time after treatment, hospital stay, and surgical outcome. All 21 patients were women with a median age of 52 years (range 36-68 years). Eighteen patients complained of frequency and urgency, four patients had dysuria, and one patient developed urinary retention. Radiation therapy was primarily indicated in the treatment of cervical cancer in 18 patients (85.7%) and endometrial cancer in three patients (14.3%). Nine patients (42.8%) received blood transfusion before surgery and three patients (14.3%) needed blood transfusion after the procedure. The mean decrease in hemoglobin prior to the procedure was 4.08 ± 2.04 g/dL. The median length of time from completion of radiotherapy to the presentation of hematuria was 38 months (range 8-65 months). All patients had failed an adequate trial of conservative treatment which included adequate hydration, hemostatics, continuous bladder irrigation (CBI), and clot evacuation at the bedside. Eleven patients (52.4%) had previously been treated with endoscopic electrocoagulation; the mean number of procedures was 1.73 ± 0.78 (range 1-3 sessions). Six patients (28.6%) underwent HBO, and sodium hyaluronate solution irrigation was administered to 3 patients (14.3%). The mean number of HBO sessions was 26.3 ± 16.8 (range 8-50), and the mean number of sodium hyaluronate solution irrigation procedures was 4.33 ± 1.53 (range 3-6). All operations were successful. The mean operative time was 45.6 ± 12.3 min, the mean number of coagulated areas was 11.7 ± 4.4, the mean energy used was 2.74 ± 1.14 kJ, the mean catheterization time was 6.2 ± 0.9 days, the mean discharge time after treatment was 6.8 ± 1.2 days, and the average length of a hospital stay was 7.4 ± 1.3 days. In 16 patients (76.2%), hematuria was completely resolved after one session of diode laser coagulation. Four patients (19.0%) underwent multiple sessions of laser treatment due to recurrent gross hematuria (three patients required two sessions and one patient required three sessions). Only one patient (4.8%) who had persistent gross hematuria after diode laser treatment (two sessions) underwent a radical cystectomy, which resolved the hematuria. The median hematuria-free interval of patients who had multiple procedures was 9 months (range 1-13 months). In total, 21 patients underwent 27 sessions of diode laser coagulation, and the median hematuria-free interval was 16 months (range 1-45 months) with a median follow-up of 25 months (range 7-48 months). Our study shows promising results for the management of patients with RHC; however, further evaluation with a larger cohort is required to confirm the efficacy of this treatment.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Traumatismos por Radiación / Coagulación con Láser / Cistitis / Láseres de Semiconductores / Hemorragia Tipo de estudio: Observational_studies Límite: Adult / Aged / Female / Humans / Middle aged Idioma: En Revista: Lasers Med Sci Asunto de la revista: BIOTECNOLOGIA / RADIOLOGIA Año: 2021 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Traumatismos por Radiación / Coagulación con Láser / Cistitis / Láseres de Semiconductores / Hemorragia Tipo de estudio: Observational_studies Límite: Adult / Aged / Female / Humans / Middle aged Idioma: En Revista: Lasers Med Sci Asunto de la revista: BIOTECNOLOGIA / RADIOLOGIA Año: 2021 Tipo del documento: Article País de afiliación: China