Your browser doesn't support javascript.
loading
Liquid chromatography-diode array-mass spectrometric analysis of amino and mercapto compounds coupled with chloroimino derivatization reagent.
Khedr, A; Khayyat, A N; El-Shorbagi, A A.
Afiliación
  • Khedr A; Department of Pharmaceutical Chemistry, Faculty of Pharmacy, King Abdulaziz University, Jeddah 21589, P.O. Box 80260, Saudi Arabia. Electronic address: akhedr@kau.edu.sa.
  • Khayyat AN; Department of Pharmaceutical Chemistry, Faculty of Pharmacy, King Abdulaziz University, Jeddah 21589, P.O. Box 80260, Saudi Arabia.
  • El-Shorbagi AA; Department of Medicinal Chemistry, Faculty of Pharmacy, Sharjah University, United Arab Emirates.
J Chromatogr A ; 1621: 461078, 2020 Jun 21.
Article en En | MEDLINE | ID: mdl-32312546
ABSTRACT
A new derivatization reagent, N-(naphthalen-1-yl)-2-oxopropanehydrazonoyl chloride (UOSA54), was prepared and coupled with four drugs, bearing primary amino, secondary amino or mercapto functional groups. Glucosamine sulfate (GLU), cysteine (CYS), captopril (CAP), and vildagliptin (VIL), were used as representative reactive analytes. The prepared reagent was successfully coupled with the targeted analytes in the presence of triethylamine (TEA) as hydrochloride acceptor and acetonitrile as solvent. The resulting reaction products were separated by high-performance liquid chromatography and monitored simultaneously by diode array and triple quad mass spectrometry detectors. Enhanced DAD and electrospray ionization-MS (ESI-MS) responses were observed for the derivatized products. Complete derivatization of VIL was achieved after heating at 65 ± 3 °C for 4 min, while other analytes were derivatized instantaneously at room temperature. Both, the ESI-ionization suppression, due to the excess reagent, and matrix effect, due to co-eluted biogenic plasma constituents, were negligible. The derivatized GLU, CYS, CAP, and VIL showed a maximum absorption wavelength at 376, 417, 340, and 376 nm, with MS-limit of quantification value of 250.0, 2.0, 2.5, and 3.0 pg/µL, respectively. The relative ESI-MS response of UOSA54 derivatization products was within the range of 0.6-4.1 compared with dansylated products. The method was optimized and validated for optimal reaction product stability, sensitivity, linearity, range, precision, and accuracy. The percentage recovery was exceeding 97.2%, with an RSD value of less than 4.0%. The limit of quantification of targeted analytes was ranged from 80.0 to 0.7 pg/µL.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Espectrometría de Masas / Compuestos de Sulfhidrilo / Cromatografía Liquida / Aminas / Iminas Idioma: En Revista: J Chromatogr A Año: 2020 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Espectrometría de Masas / Compuestos de Sulfhidrilo / Cromatografía Liquida / Aminas / Iminas Idioma: En Revista: J Chromatogr A Año: 2020 Tipo del documento: Article