Your browser doesn't support javascript.
loading
The strategy of cardiopulmonary bypass for total aortic arch replacement and the frozen elephant trunk technique with aortic balloon occlusion.
Li, Yunfeng; Yan, Shujie; Lou, Song; Sun, Xiaogang.
Afiliación
  • Li Y; Aortic and Vascular Surgery Centre, Fuwai Hospital, National Centre for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.
  • Yan S; Department of Adult Cardiopulmonary Bypass, Fuwai Hospital, National Centre for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.
  • Lou S; Department of Adult Cardiopulmonary Bypass, Fuwai Hospital, National Centre for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.
  • Sun X; Aortic and Vascular Surgery Centre, Fuwai Hospital, National Centre for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.
J Int Med Res ; 48(5): 300060520905410, 2020 May.
Article en En | MEDLINE | ID: mdl-32357091
ABSTRACT

OBJECTIVE:

To investigate the use of the aortic balloon occlusion technique to assist total aortic arch replacement (TAR) with frozen elephant trunk (FET) to shorten the lower body circulatory arrest (CA) time and raise the nadir temperature during cardiopulmonary bypass.

METHODS:

This retrospective study reviewed consecutive patients that underwent aortic balloon occlusion to assist TAR with FET and patients that received conventional TAR with FET procedures. Preoperative characteristics, perioperative characteristics and postoperative outcomes were compared between the two groups.

RESULTS:

The study included130 patients treated with aortic balloon occlusion and 230 patients treated with conventional TAR with FET. The 30-day mortality rate was similar between the aortic balloon occlusion and conventional groups (4.62% versus 7.83%, respectively). Multivariate analysis showed that aortic balloon occlusion reduced the incidence of acute kidney injury, hepatic injury and red blood cell transfusion. The application of aortic balloon occlusion reduced the mean ± SD CA time from 17.24 ± 4.36 min to 6.33 ± 5.74 min, with the target nadir nasal temperature being increased from 25°C to 28°C.

CONCLUSION:

The aortic balloon occlusion technique achieved significant improvements in reducing complications, but this did not translate into lower 30-day mortality.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Enfermedades de la Aorta / Complicaciones Posoperatorias / Puente Cardiopulmonar / Implantación de Prótesis Vascular / Oclusión con Balón Tipo de estudio: Etiology_studies / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: J Int Med Res Año: 2020 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Enfermedades de la Aorta / Complicaciones Posoperatorias / Puente Cardiopulmonar / Implantación de Prótesis Vascular / Oclusión con Balón Tipo de estudio: Etiology_studies / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: J Int Med Res Año: 2020 Tipo del documento: Article País de afiliación: China