Evaluation of scattered radiation dose received by medical staff during uterine artery embolization in the operating room.
Technol Health Care
; 28(S1): 3-11, 2020.
Article
en En
| MEDLINE
| ID: mdl-32364139
BACKGROUND: The air kerma radiation doses have gained much attention since the operating room interventional radiology is a place where medical staff are exposed to a fluoroscopy environment and gain a cumulative dose during the uterine artery embolization procedure. OBJECTIVE: We aimed to evaluate the radiation dose received by medical staff by applying a flat X-ray machine in the surgical room during uterine artery embolization. METHODS: An ATOM humanoid model was laid on the operating table and simulated a patient. The scattered radiation dose received by the radiologist, anesthetist and radiologic technologist was evaluated. The scintillation detector was adopted. The measurement points were 50 cm, 100 cm and 150 cm above the floor, representing the limbs, abdomen and thyroid level, respectively. We compared the X-rays under different tube voltages of 70, 80, and 90, respectively and frames per second (FPS) of 30, 15, and 7.5, respectively. We configured the dose level per pulse of 40 nGy with a fixed detector. RESULTS: In Section 1, when the tube voltage was 70 kVp and 7.5 FPS, the average radiation doses of limbs, abdomen and thyroid level was 0.48, 1.3 and 1.9 µSv/min respectively. When the tube voltage was 80 kVp and the fluoroscopy decreases from 30 FPS to 7.5 FPS, 58% of the radiation dose was reduced. When the tube voltage was 90 kVp, the radiation dose in the lead garment increased 31-177% in comparison to when the tube voltage was 80 kVp. Sections 2 and 3 were far away from the central ray, so the highest radiation dose 100 cm above the floor were 0.05 and 0.02 µSv/min. CONCLUSIONS: Lead garment can effectively reduce medical staff from occupational doses with an average attenuation rate of 90%. 80 kVp was most commonly used. Fluoroscopy 7.5 FPS was used 100 cm above the floor in A section and the lowest radiation dose was 1.33 µSv/min. The operator should decrease the duration of X-rays or adopt suspended lead shielding to decrease the radiation dose received by the operator. When kVp increases, the penetration increases. Decreasing FPS cannot decrease occupational doses of medical staff.
Palabras clave
Texto completo:
1
Colección:
01-internacional
Base de datos:
MEDLINE
Asunto principal:
Dosis de Radiación
/
Radiología Intervencionista
/
Exposición Profesional
/
Exposición a la Radiación
/
Embolización de la Arteria Uterina
Tipo de estudio:
Prognostic_studies
Límite:
Humans
Idioma:
En
Revista:
Technol Health Care
Asunto de la revista:
ENGENHARIA BIOMEDICA
/
SERVICOS DE SAUDE
Año:
2020
Tipo del documento:
Article
Pais de publicación:
Países Bajos