Your browser doesn't support javascript.
loading
Computed Tomography-Aortography Versus Color-Duplex Ultrasound for Surveillance of Endovascular Abdominal Aortic Aneurysm Repair: A Prospective Multicenter Diagnostic-Accuracy Study (the ESSEA Trial).
Jean-Baptiste, Elixène; Feugier, Patrick; Cruzel, Coralie; Sarlon-Bartoli, Gabrielle; Reix, Thierry; Steinmetz, Eric; Chaufour, Xavier; Chavent, Bertrand; Salomon du Mont, Lucie; Ejargue, Meghann; Maurel, Blandine; Spear, Rafaelle; Midy, Dominique; Thaveau, Fabien; Desgranges, Pascal; Rosset, Eugenio; Hassen-Khodja, Réda.
Afiliación
  • Jean-Baptiste E; Service de Chirurgie Vasculaire, INSERM U1065, CHU de Nice, Université Côte D'Azur, Nice, France (E.J.-B., R.H.-K.).
  • Feugier P; Service de Chirurgie Vasculaire, CHU Edouard Herriot, Université Claude Bernard Lyon1, Lyon, France (P.F.).
  • Cruzel C; Délégation à la Recherche Clinique et à l'innovation, CHU de Nice, Université Côte D'Azur, Nice, France (C.C.).
  • Sarlon-Bartoli G; C2VN, APHM, CHU Timone, Service de Chirurgie Vasculaire, Aix Marseille Université, Marseille, France (G.S.-B.).
  • Reix T; Service de Chirurgie Vasculaire, CHU Amiens-Picardie, Université de Picardie Jules Verne, Amiens, France (T.R.).
  • Steinmetz E; Service de Chirurgie Vasculaire, CHU Dijon-Bourgogne, Université de Bourgogne, Dijon, France (E.S.).
  • Chaufour X; Service de Chirurgie Vasculaire et angiologie, CHU de Toulouse, Université Paul Sabatier, Toulouse, France (X.C.).
  • Chavent B; Service de Chirurgie Cardio-Vasculaire, CHU de Saint-Etienne, Université Jean Monnet, Saint-Etienne, France (B.C.).
  • Salomon du Mont L; Service de Chirurgie Vasculaire et Endovasculaire, CHU de Besançon, Université de Franche-Comté, Besançon, France (L.S.d.M.).
  • Ejargue M; AP-HM, Department of Vascular Surgery, University Hospital Nord, Aix-Marseille Université, Marseille, France (M.E.).
  • Maurel B; CHU Nantes, l'institut du thorax, service de chirurgie vasculaire, Inserm-UN UMR-957, Nantes, France (B.M.).
  • Spear R; Service de Chirurgie Vasculaire, CHU de Grenoble, Université Grenoble-Alpes, Grenoble, France (R.S.).
  • Midy D; Service de Chirurgie Vasculaire, CHU de Bordeaux, Bordeaux, France (D.M.).
  • Thaveau F; Service de Chirurgie Vasculaire, CHU de Strasbourg, Strasbourg, France (F.T.).
  • Desgranges P; Service de Chirurgie Vasculaire, CHU Henri Mondor, Créteil, France (P.D.).
  • Rosset E; Service de Chirurgie Vasculaire, CHU de Clermont-Ferrand, Université d'Auvergne, Clermont-Ferrand, France (E.R.).
  • Hassen-Khodja R; Service de Chirurgie Vasculaire, INSERM U1065, CHU de Nice, Université Côte D'Azur, Nice, France (E.J.-B., R.H.-K.).
Circ Cardiovasc Imaging ; 13(6): e009886, 2020 06.
Article en En | MEDLINE | ID: mdl-32507018
ABSTRACT
Background Color-duplex ultrasonography (DUS) could be an alternative to computed tomography-aortography (CTA) in the lifelong surveillance of patients after endovascular aneurysm repair (EVAR), but there is currently no level 1 evidence. The aim of this study was to assess the diagnostic accuracy of DUS as an alternative to CTA for the follow-up of post-EVAR patients. Methods Between December 16, 2010, and June 12, 2015, we conducted a prospective, blinded, diagnostic-accuracy study, in 15 French university hospitals where EVAR was commonly performed. Participants were followed up using both DUS and CTA in a mutually blinded setup until the end of the study or until any major aneurysm-related morphological abnormality requiring reintervention or an amendment to the follow-up policy was revealed by CTA. Database was locked on October 2, 2017. Our main outcome measures were sensitivity, specificity, positive predictive value, negative predictive value, positive and negative likelihood ratios of DUS against reference standard CTA. CIs are binomial 95% CI. Results This study recruited prospectively 659 post-EVAR patients of whom 539 (82%) were eligible for further analysis. Following the baseline inclusion visit, 940 additional follow-up visits were performed in the 539 patients. Major aneurysm-related morphological abnormalities were revealed by CTA in 103 patients (17.2/100 person-years [95% CI, 13.9-20.5]). DUS accurately identified 40 patients where a major aneurysm-related morphological abnormality was present (sensitivity, 39% [95% CI, 29-48]) and 403 of 436 patients with negative CTA (specificity, 92% [95% CI, 90-95]). The negative predictive value and positive predictive value of DUS were 92% (95% CI, 90-95) and 39% (95% CI, 27-50), respectively. The positive likelihood ratio was 4.87 (95% CI, 2.9-9.6). DUS sensitivity reached 73% (95% CI, 51-96) in patients requiring an effective reintervention. Conclusions DUS had an overall low sensitivity in the follow-up of patients after EVAR, but its performance improved meaningfully when the subset of patients requiring effective reinterventions was considered. Registration URL https//www.clinicaltrials.gov; Unique identifier NCT01230203.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Complicaciones Posoperatorias / Aortografía / Aneurisma de la Aorta Abdominal / Ultrasonografía Doppler en Color / Implantación de Prótesis Vascular / Procedimientos Endovasculares / Tomografía Computarizada Multidetector / Angiografía por Tomografía Computarizada Tipo de estudio: Clinical_trials / Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies / Screening_studies Límite: Aged / Aged80 / Female / Humans / Male País/Región como asunto: Europa Idioma: En Revista: Circ Cardiovasc Imaging Asunto de la revista: ANGIOLOGIA / CARDIOLOGIA / DIAGNOSTICO POR IMAGEM Año: 2020 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Complicaciones Posoperatorias / Aortografía / Aneurisma de la Aorta Abdominal / Ultrasonografía Doppler en Color / Implantación de Prótesis Vascular / Procedimientos Endovasculares / Tomografía Computarizada Multidetector / Angiografía por Tomografía Computarizada Tipo de estudio: Clinical_trials / Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies / Screening_studies Límite: Aged / Aged80 / Female / Humans / Male País/Región como asunto: Europa Idioma: En Revista: Circ Cardiovasc Imaging Asunto de la revista: ANGIOLOGIA / CARDIOLOGIA / DIAGNOSTICO POR IMAGEM Año: 2020 Tipo del documento: Article
...