Gastrografin can be detected in ex vivo biological specimens by dual-energy CT scanning.
Clark, David A; Yeoh, Edward; Edmundson, Aleksandra; Pratap, Jit; Snow, Tom; Solomon, Michael; Coucher, John.
Afiliación
  • Clark DA; Faculty of Medicine and Health, University of Sydney, Sydney, New South Wales, Australia.
  • Yeoh E; Department of Surgery, Royal Brisbane and Women's Hospital, Brisbane, Queensland, Australia.
  • Edmundson A; Faculty of Medicine, University of Queensland, St Lucia, Brisbane, Queensland, Australia.
  • Pratap J; St Vincent's Private Hospital Northside, Brisbane, Queensland, Australia.
  • Snow T; Department of Medical Imaging, Princess Alexandra Hospital, Brisbane, Queensland, Australia.
  • Solomon M; Department of Surgery, Royal Brisbane and Women's Hospital, Brisbane, Queensland, Australia.
  • Coucher J; Faculty of Medicine, University of Queensland, St Lucia, Brisbane, Queensland, Australia.
J Med Imaging Radiat Oncol ; 64(5): 634-640, 2020 Oct.
Article en En | MEDLINE | ID: mdl-32543123
ABSTRACT

BACKGROUND:

Dual-energy CT is able to distinguish between materials based on differences in X-ray absorption at different X-ray beam energies. The strong k-edge photoelectric effect of materials with a high atomic number makes this modality ideal for identifying iodine-containing compounds. We aim to evaluate dual-energy CT for the detection of Gastrografin (GG) (diatrizoate, Bayer PLC, Reading, UK) enteric contrast medium and validate the conditions for the measurement in ex vivo samples.

METHODS:

Dual-energy CT acquisitions were performed to detect Gastrografin in serial dilutions of water, saline and body fluids. We also evaluated the stability of Gastrografin solutions over time at room temperature. Stool specimens were examined to validate the proposed study protocol for clinical applications.

RESULTS:

Concentrations as low as 0.2% of Gastrografin were reproducibly detected in vitro and ex vivo samples by DECT, with linear readings ranging from 0.2% to 25% Gastrografin. Gastrografin was shown to be stable in ex vivo biological samples, and there was no difference in detection over time. Gastrografin was detected in stool specimens when administered orally. The detection curves followed the expected saturation effect at high concentrations of iodine.

CONCLUSIONS:

Dual-energy CT offers a convenient, quick, reliable and reproducible method for detecting and quantifying the presence of Gastrografin in ex vivo clinical specimens. Biological solutions containing Gastrografin are stable over time. A minimum dilution level of 25% is suggested to avoid beam saturation and inaccurate results.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Diatrizoato de Meglumina / Tomografía Computarizada por Rayos X / Medios de Contraste / Heces Tipo de estudio: Guideline / Prognostic_studies Límite: Humans Idioma: En Revista: J Med Imaging Radiat Oncol Asunto de la revista: DIAGNOSTICO POR IMAGEM / NEOPLASIAS / RADIOLOGIA Año: 2020 Tipo del documento: Article País de afiliación: Australia

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Diatrizoato de Meglumina / Tomografía Computarizada por Rayos X / Medios de Contraste / Heces Tipo de estudio: Guideline / Prognostic_studies Límite: Humans Idioma: En Revista: J Med Imaging Radiat Oncol Asunto de la revista: DIAGNOSTICO POR IMAGEM / NEOPLASIAS / RADIOLOGIA Año: 2020 Tipo del documento: Article País de afiliación: Australia