The Development of Spectrophotometric and Validated Stability- Indicating RP-HPLC Methods for Simultaneous Determination of Ephedrine HCL, Naphazoline HCL, Antazoline HCL, and Chlorobutanol in Pharmaceutical Pomade Form.
Dindar, Çigdem K; Erkmen, Cem; Uslu, Bengi; Göger, Nilgün G.
Afiliación
  • Dindar ÇK; Department of Analytical Chemistry, Faculty of Pharmacy, Gazi University, Ankara 06330, Turkey.
  • Erkmen C; Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, Ankara 06330, Turkey.
  • Uslu B; Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, Ankara 06330, Turkey.
  • Göger NG; Department of Analytical Chemistry, Faculty of Pharmacy, Gazi University, Ankara 06330, Turkey.
Comb Chem High Throughput Screen ; 23(10): 1090-1099, 2020.
Article en En | MEDLINE | ID: mdl-32691707
BACKGROUND: Allergic rhinitis, acute nasal congestion and sinusitis are one of the most common health problems and have a major effect on the quality of life. Several medications are used to improve the symptoms of such diseases in humans. Pharmaceutical pomade form containing Ephedrine (EPD) HCl, Naphazoline (NPZ) HCl, Antazoline (ANT) HCl, and Chlorobutanol (CLO) is one of them. OBJECTIVE: For these reasons, this study includes the development of spectrophotometric and chromatographic methods for the determination of EPD HCl, NPZ HCl, ANT HCl, and CLO active agents in the pharmaceutical pomade. METHOD: In the spectrophotometric method, third-order derivative of the amplitudes at 218 nm n=5 and the first-order derivative of the amplitudes 254 nm n=13 was selected for the determination of EPD, ANT, respectively while NPZ was determined by the second derivative at 234 nm and n=21. Colorimetric detection was applied for assay analysis of CLO at 540 nm. Furthermore, a reverse phase high performance liquid chromatographic (RP- HPLC) method has been developed and optimized by using Agilent Zorbax Eclipse XDB C18 (75 mm x 3.0 mm, 3.5µm) column. The column temperature was 40°C, binary gradient elution was used and the mobile phase consisted of 15 mM phosphate buffer in distilled water (pH 3.0) and methanol, and the flow rate was 0.6 mL min-1 and the UV detector was detected at 210 nm. The linear operating range was obtained as 11.97-70, 0.59-3, 2.79-30, and 2.92-200 µg mL-1 for EPD HCl, NPZ HCl, ANT HCl, and CLO respectively. RESULTS: The LOD values were found to be 3.95, 0.19, 0.92 and 0.96 µg mL-1 for EPD HCl, NPZ HCl, ANT HCl, and CLO in the spectrophotometric method, respectively. The linear ranges in the RP-HPLC method were 8.2-24.36 µg mL-1, 0.083 - 0.75 µg/mL, 2.01-7.5 µg mL-1 and 2.89-24.4 µg mL-1 for EPD HCl, NPZ HCl, ANT HCl, and CLO, respectively. The LOD values in the validation studies were 2.7, 0.025, 0.66 and 0.86 µg mL-1 for EPD HCl, NPZ HCl, ANT HCl, and CLO in RP-HPLC method respectively. CONCLUSION: The results of the spectrophotometric and chromatographic methods were compared and no differences were found between the two methods.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Clorobutanol / Efedrina / Antazolina / Nafazolina Aspecto: Patient_preference Idioma: En Revista: Comb Chem High Throughput Screen Asunto de la revista: BIOLOGIA MOLECULAR / QUIMICA Año: 2020 Tipo del documento: Article País de afiliación: Turquía Pais de publicación: Emiratos Árabes Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Clorobutanol / Efedrina / Antazolina / Nafazolina Aspecto: Patient_preference Idioma: En Revista: Comb Chem High Throughput Screen Asunto de la revista: BIOLOGIA MOLECULAR / QUIMICA Año: 2020 Tipo del documento: Article País de afiliación: Turquía Pais de publicación: Emiratos Árabes Unidos