Your browser doesn't support javascript.
loading
A tailored positively-charged hydrophobic surface reduces the risk of implant associated infections.
Shen, Jie; Gao, Peng; Han, Shan; Kao, Richard Y T; Wu, Shuilin; Liu, Xuanyong; Qian, Shi; Chu, Paul K; Cheung, Kenneth M C; Yeung, Kelvin W K.
Afiliación
  • Shen J; Department of Orthopaedics and Traumatology, The University of Hong Kong, Hong Kong SAR, PR China; Shenzhen Key Laboratory for Innovative Technology in Orthopaedic Trauma, The University of Hong Kong Shenzhen Hospital, Shenzhen, PR China.
  • Gao P; Department of Microbiology, The University of Hong Kong, Hong Kong SAR, PR China.
  • Han S; Department of Orthopaedics and Traumatology, The University of Hong Kong, Hong Kong SAR, PR China.
  • Kao RYT; Department of Microbiology, The University of Hong Kong, Hong Kong SAR, PR China.
  • Wu S; School of Materials Science & Engineering, the Key Laboratory of Advanced Ceramics and Machining Technology by the Ministry of Education of China, Tianjin University, Tianjin, PR China.
  • Liu X; State Key Laboratory of High Performance Ceramics and Superfine Microstructure, Shanghai Institute of Ceramics, Chinese Academy of Sciences, Shanghai, PR China; Cixi Center of Biomaterials Surface Engineering, Shanghai Institute of Ceramics, Chinese Academy of Sciences, Ningbo, PR China.
  • Qian S; Cixi Center of Biomaterials Surface Engineering, Shanghai Institute of Ceramics, Chinese Academy of Sciences, Ningbo, PR China.
  • Chu PK; Department of Physics and Department of Materials Science and Engineering, City University of Hong Kong, Hong Kong SAR, PR China.
  • Cheung KMC; Department of Orthopaedics and Traumatology, The University of Hong Kong, Hong Kong SAR, PR China; Shenzhen Key Laboratory for Innovative Technology in Orthopaedic Trauma, The University of Hong Kong Shenzhen Hospital, Shenzhen, PR China.
  • Yeung KWK; Department of Orthopaedics and Traumatology, The University of Hong Kong, Hong Kong SAR, PR China; Shenzhen Key Laboratory for Innovative Technology in Orthopaedic Trauma, The University of Hong Kong Shenzhen Hospital, Shenzhen, PR China. Electronic address: wkkyeung@hku.hk.
Acta Biomater ; 114: 421-430, 2020 09 15.
Article en En | MEDLINE | ID: mdl-32711080
ABSTRACT
Implant-associated infections is one of the most challenging post-operative complications in bone-related implantations. To tackle this clinical issue, we developed a low-cost and durable surface coating for medical grade titanium implants that uses positively charged silane molecules. The in vitro antimicrobial tests revealed that the titanium surface coated with (3-aminopropyl) triethoxysilane, which has the appropriate length of hydrophobic alkyl chain and positive charged amino group, suppressed more than 90% of the initial bacterial adhesion of S. aureus, P. aeruginosa, and E. coli after 30 min of incubation. In terms of growth inhibitory rate, the treated surface was able to reduce 75.7% ± 11.9% of bacterial growth after a 24-hour culturing, thereby exhibiting superior anti-biofilm formation in the late stage. When implanted into the rat model infected by S. aureus, the treated surface eliminated the implant-associated infection through the mechanism of inhibition of bacterial adhesion on the implant surface. Additionally, the treated surface was highly compatible with mammalian cells. In general, our design demonstrated its potential for human clinical trials as a low-cost and effective antibacterial strategy to minimize post-operative implant-related bacterial infection.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Staphylococcus aureus / Materiales Biocompatibles Revestidos Tipo de estudio: Etiology_studies / Risk_factors_studies Límite: Animals Idioma: En Revista: Acta Biomater Año: 2020 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Staphylococcus aureus / Materiales Biocompatibles Revestidos Tipo de estudio: Etiology_studies / Risk_factors_studies Límite: Animals Idioma: En Revista: Acta Biomater Año: 2020 Tipo del documento: Article