Your browser doesn't support javascript.
loading
Use of Stainless-Steel, Balloon-Expandable Chimney Grafts Is Durable Though Caution Is Required When Lining Angulated Renal Arteries.
Taneva, Gergana T; Fazzini, Stefano; Pipitone, Marco Damiano; Karaolanis, Georgios; Torsello, Giovanni; Bremer, Christoph; Austermann, Martin; Donas, Konstantinos P.
Afiliación
  • Taneva GT; Department of Vascular Surgery, Research Vascular Centre, Asklepios Clinic Langen, University of Frankfurt, Germany.
  • Fazzini S; Department of Vascular Surgery, St Franziskus Hospital Münster, Germany.
  • Pipitone MD; Department of Vascular Surgery, St Franziskus Hospital Münster, Germany.
  • Karaolanis G; Department of Vascular Surgery, St Franziskus Hospital Münster, Germany.
  • Torsello G; Department of Vascular Surgery, St Franziskus Hospital Münster, Germany.
  • Bremer C; Department of Radiology, St Franziskus Hospital Münster, Germany.
  • Austermann M; Department of Vascular Surgery, St Franziskus Hospital Münster, Germany.
  • Donas KP; Department of Vascular Surgery, Research Vascular Centre, Asklepios Clinic Langen, University of Frankfurt, Germany.
J Endovasc Ther ; 27(6): 902-909, 2020 Dec.
Article en En | MEDLINE | ID: mdl-32813593
PURPOSE: To analyze the overall performance of flexible nitinol stents used to line chimney grafts (CGs) during chimney endovascular aneurysm repair (chEVAR) of pararenal pathologies. MATERIALS AND METHODS: A retrospective review was conducted of all 116 elective patients (mean age 74.3±7.2 years; 103 men) who underwent chEVAR with balloon-expandable Advanta V12/iCAST CGs in combination with the Endurant stent-graft between January 2009 and December 2017 at a single center. CG lining with a nitinol stent was electively performed in 43 target vessels of 32 patients. The Kaplan-Meier method was used to estimate the primary outcomes of CG patency and freedom from reintervention (FFR) at the patient level and according to the use of a stent to line the CG. Estimates are reported with the 95% confidence interval (CI). Adjusted odds ratios (ORs) were calculated to identify any confounding effect between the presence/absence of a stent lining or according to the number of CGs. RESULTS: The mean radiological follow-up was 27.3 months (range 22.1-32.6). During this time, 8 CGs (4.7%) became occluded, 6 of them were lined with stents. Restoration of patency was possible in 3 of the 4 occluded stents that were associated with symptoms. First-year primary patency estimates were 96.9% (95% CI 92.5% to 100%) for the unlined group vs 77.1% (95% CI 58% to 95.3%; p=0.001) for the lined group, while FFR was 87.6% (95% CI 79.9% to 95.2%) vs 83.4% (95% CI 68.1% to 98.6%; p=0.82), respectively. Lining represented an independent risk factor for CG occlusion (OR 9.9, p=0.006). CONCLUSION: CG lining performed mainly in angulated renal arteries during chEVAR was significantly associated with CG occlusion. These findings highlight the importance of not having the distal part of the CG impinge on the angulated segment of the target vessel.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Arteria Renal / Stents / Implantación de Prótesis Vascular / Procedimientos Endovasculares / Aneurisma Tipo de estudio: Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Aged / Aged80 / Female / Humans / Male Idioma: En Revista: J Endovasc Ther Asunto de la revista: ANGIOLOGIA Año: 2020 Tipo del documento: Article País de afiliación: Alemania Pais de publicación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Arteria Renal / Stents / Implantación de Prótesis Vascular / Procedimientos Endovasculares / Aneurisma Tipo de estudio: Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Aged / Aged80 / Female / Humans / Male Idioma: En Revista: J Endovasc Ther Asunto de la revista: ANGIOLOGIA Año: 2020 Tipo del documento: Article País de afiliación: Alemania Pais de publicación: Estados Unidos