Your browser doesn't support javascript.
loading
Estimating partial-body ionizing radiation exposure by automated cytogenetic biodosimetry.
Shirley, Ben C; Knoll, Joan H M; Moquet, Jayne; Ainsbury, Elizabeth; Pham, Ngoc-Duy; Norton, Farrah; Wilkins, Ruth C; Rogan, Peter K.
Afiliación
  • Shirley BC; CytoGnomix Inc., London, Canada.
  • Knoll JHM; CytoGnomix Inc., London, Canada.
  • Moquet J; Department of Pathology and Laboratory Medicine, University of Western Ontario, London, Canada.
  • Ainsbury E; Public Health England, Oxford, Great Britain.
  • Pham ND; Public Health England, Oxford, Great Britain.
  • Norton F; Dalat Nuclear Research Institute, Dalat, Vietnam.
  • Wilkins RC; Canadian Nuclear Laboratories, Chalk River, Canada.
  • Rogan PK; Health Canada, Ottawa, Canada.
Int J Radiat Biol ; 96(11): 1492-1503, 2020 11.
Article en En | MEDLINE | ID: mdl-32910711
ABSTRACT

PURPOSE:

Inhomogeneous exposures to ionizing radiation can be detected and quantified with the dicentric chromosome assay (DCA) of metaphase cells. Complete automation of interpretation of the DCA for whole-body irradiation has significantly improved throughput without compromising accuracy, however, low levels of residual false positive dicentric chromosomes (DCs) have confounded its application for partial-body exposure determination. MATERIALS AND

METHODS:

We describe a method of estimating and correcting for false positive DCs in digitally processed images of metaphase cells. Nearly all DCs detected in unirradiated calibration samples are introduced by digital image processing. DC frequencies of irradiated calibration samples and those exposed to unknown radiation levels are corrected subtracting this false positive fraction from each. In partial-body exposures, the fraction of cells exposed, and radiation dose can be quantified after applying this modification of the contaminated Poisson method.

RESULTS:

Dose estimates of three partially irradiated samples diverged 0.2-2.5 Gy from physical doses and irradiated cell fractions deviated by 2.3%-15.8% from the known levels. Synthetic partial-body samples comprised of unirradiated and 3 Gy samples from 4 laboratories were correctly discriminated as inhomogeneous by multiple criteria. Root mean squared errors of these dose estimates ranged from 0.52 to 1.14 Gy2 and from 8.1 to 33.3%2 for the fraction of cells irradiated.

CONCLUSIONS:

Automated DCA can differentiate whole- from partial-body radiation exposures and provides timely quantification of estimated whole-body equivalent dose.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Radiometría / Exposición a la Radiación / Análisis Citogenético Límite: Humans Idioma: En Revista: Int J Radiat Biol Asunto de la revista: RADIOLOGIA Año: 2020 Tipo del documento: Article País de afiliación: Canadá

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Radiometría / Exposición a la Radiación / Análisis Citogenético Límite: Humans Idioma: En Revista: Int J Radiat Biol Asunto de la revista: RADIOLOGIA Año: 2020 Tipo del documento: Article País de afiliación: Canadá
...