Automatic segmentation and applicator reconstruction for CT-based brachytherapy of cervical cancer using 3D convolutional neural networks.
Zhang, Daguang; Yang, Zhiyong; Jiang, Shan; Zhou, Zeyang; Meng, Maobin; Wang, Wei.
Afiliación
  • Zhang D; School of Mechanical Engineering, Tianjin University, Tianjin, China.
  • Yang Z; School of Mechanical Engineering, Tianjin University, Tianjin, China.
  • Jiang S; School of Mechanical Engineering, Tianjin University, Tianjin, China.
  • Zhou Z; School of Mechanical Engineering, Tianjin University, Tianjin, China.
  • Meng M; Department of Radiation Oncology, Tianjin Medical University Cancer Institute and Hospital, Tianjin, China.
  • Wang W; Department of Radiation Oncology, Tianjin Medical University Cancer Institute and Hospital, Tianjin, China.
J Appl Clin Med Phys ; 21(10): 158-169, 2020 Oct.
Article en En | MEDLINE | ID: mdl-32991783
In this study, we present deep learning-based approaches to automatic segmentation and applicator reconstruction with high accuracy and efficiency in the planning computed tomography (CT) for cervical cancer brachytherapy (BT). A novel three-dimensional (3D) convolutional neural network (CNN) architecture was proposed and referred to as DSD-UNET. The dataset of 91 patients received CT-based BT of cervical cancer was used to train and test DSD-UNET model for auto-segmentation of high-risk clinical target volume (HR-CTV) and organs at risk (OARs). Automatic applicator reconstruction was achieved with DSD-UNET-based segmentation of applicator components followed by 3D skeletonization and polynomial curve fitting. Digitization of the channel paths for tandem and ovoid applicator in the planning CT was evaluated utilizing the data from 32 patients. Dice similarity coefficient (DSC), Jaccard Index (JI), and Hausdorff distance (HD) were used to quantitatively evaluate the accuracy. The segmentation performance of DSD-UNET was compared with that of 3D U-Net. Results showed that DSD-UNET method outperformed 3D U-Net on segmentations of all the structures. The mean DSC values of DSD-UNET method were 86.9%, 82.9%, and 82.1% for bladder, HR-CTV, and rectum, respectively. For the performance of automatic applicator reconstruction, outstanding segmentation accuracy was first achieved for the intrauterine and ovoid tubes (average DSC value of 92.1%, average HD value of 2.3 mm). Finally, HDs between the channel paths determined automatically and manually were 0.88 ± 0.12 mm, 0.95 ± 0.16 mm, and 0.96 ± 0.15 mm for the intrauterine, left ovoid, and right ovoid tubes, respectively. The proposed DSD-UNET method outperformed the 3D U-Net and could segment HR-CTV, bladder, and rectum with relatively good accuracy. Accurate digitization of the channel paths could be achieved with the DSD-UNET-based method. The proposed approaches could be useful to improve the efficiency and consistency of treatment planning for cervical cancer BT.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Braquiterapia / Neoplasias del Cuello Uterino Tipo de estudio: Etiology_studies Límite: Female / Humans Idioma: En Revista: J Appl Clin Med Phys Asunto de la revista: BIOFISICA Año: 2020 Tipo del documento: Article País de afiliación: China Pais de publicación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Braquiterapia / Neoplasias del Cuello Uterino Tipo de estudio: Etiology_studies Límite: Female / Humans Idioma: En Revista: J Appl Clin Med Phys Asunto de la revista: BIOFISICA Año: 2020 Tipo del documento: Article País de afiliación: China Pais de publicación: Estados Unidos