Your browser doesn't support javascript.
loading
In vivo measurement of shear modulus of the human cornea using optical coherence elastography.
Ramier, Antoine; Eltony, Amira M; Chen, YiTong; Clouser, Fatima; Birkenfeld, Judith S; Watts, Amy; Yun, Seok-Hyun.
Afiliación
  • Ramier A; Wellman Center for Photomedicine and Harvard Medical School, Massachusetts General Hospital, 50 Blossom St., Boston, MA, USA.
  • Eltony AM; Harvard-MIT Division of Health Sciences and Technology, Cambridge, MA, USA.
  • Chen Y; Wellman Center for Photomedicine and Harvard Medical School, Massachusetts General Hospital, 50 Blossom St., Boston, MA, USA.
  • Clouser F; Wellman Center for Photomedicine and Harvard Medical School, Massachusetts General Hospital, 50 Blossom St., Boston, MA, USA.
  • Birkenfeld JS; Department of Automation, Tsinghua University, Beijing, 100084, China.
  • Watts A; Wellman Center for Photomedicine and Harvard Medical School, Massachusetts General Hospital, 50 Blossom St., Boston, MA, USA.
  • Yun SH; Wellman Center for Photomedicine and Harvard Medical School, Massachusetts General Hospital, 50 Blossom St., Boston, MA, USA.
Sci Rep ; 10(1): 17366, 2020 10 15.
Article en En | MEDLINE | ID: mdl-33060714
ABSTRACT
Corneal stiffness plays a critical role in shaping the cornea with respect to intraocular pressure and physical interventions. However, it remains difficult to measure the mechanical properties noninvasively. Here, we report the first measurement of shear modulus in human corneas in vivo using optical coherence elastography (OCE) based on surface elastic waves. In a pilot study of 12 healthy subjects aged between 25 and 67, the Rayleigh-wave speed was 7.86 ± 0.75 m/s, corresponding to a shear modulus of 72 ± 14 kPa. Our data reveal two unexpected trends no correlation was found between the wave speed and IOP between 13-18 mmHg, and shear modulus decreases with age (- 0.32 ± 0.17 m/s per decade). We propose that shear stiffness is governed by the interfibrillar matrix, whereas tensile strength is dominated by collagen fibrils. Rayleigh-wave OCE may prove useful for clinical diagnosis, refractive surgeries, and treatment monitoring.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Estrés Mecánico / Córnea / Tomografía de Coherencia Óptica / Diagnóstico por Imagen de Elasticidad Tipo de estudio: Diagnostic_studies Límite: Adult / Aged / Humans / Middle aged Idioma: En Revista: Sci Rep Año: 2020 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Estrés Mecánico / Córnea / Tomografía de Coherencia Óptica / Diagnóstico por Imagen de Elasticidad Tipo de estudio: Diagnostic_studies Límite: Adult / Aged / Humans / Middle aged Idioma: En Revista: Sci Rep Año: 2020 Tipo del documento: Article País de afiliación: Estados Unidos