Your browser doesn't support javascript.
loading
Ferromagnetic Resonance Assisted Optomechanical Magnetometer.
Colombano, M F; Arregui, G; Bonell, F; Capuj, N E; Chavez-Angel, E; Pitanti, A; Valenzuela, S O; Sotomayor-Torres, C M; Navarro-Urrios, D; Costache, M V.
Afiliación
  • Colombano MF; Catalan Institute of Nanoscience and Nanotechnology (ICN2), CSIC and BIST, Campus UAB, Bellaterra, 08193 Barcelona, Spain.
  • Arregui G; Departamento de Física, Universitat Autònoma de Barcelona, 08193 Bellaterra, Spain.
  • Bonell F; Catalan Institute of Nanoscience and Nanotechnology (ICN2), CSIC and BIST, Campus UAB, Bellaterra, 08193 Barcelona, Spain.
  • Capuj NE; Departamento de Física, Universitat Autònoma de Barcelona, 08193 Bellaterra, Spain.
  • Chavez-Angel E; Catalan Institute of Nanoscience and Nanotechnology (ICN2), CSIC and BIST, Campus UAB, Bellaterra, 08193 Barcelona, Spain.
  • Pitanti A; Departamento Física, Universidad de La Laguna, 38200 San Cristóbal de La Laguna, Spain.
  • Valenzuela SO; Instituto Universitario de Materiales y Nanotecnología, Universidad de La Laguna, 38071 Santa Cruz de Tenerife, Spain.
  • Sotomayor-Torres CM; Catalan Institute of Nanoscience and Nanotechnology (ICN2), CSIC and BIST, Campus UAB, Bellaterra, 08193 Barcelona, Spain.
  • Navarro-Urrios D; NEST, CNR-Istituto Nanoscienze and Scuola Normale Superiore, Piazza San Silvestro 12, 56127 Pisa, Italy.
  • Costache MV; Catalan Institute of Nanoscience and Nanotechnology (ICN2), CSIC and BIST, Campus UAB, Bellaterra, 08193 Barcelona, Spain.
Phys Rev Lett ; 125(14): 147201, 2020 Oct 02.
Article en En | MEDLINE | ID: mdl-33064528
ABSTRACT
The resonant enhancement of mechanical and optical interaction in optomechanical cavities enables their use as extremely sensitive displacement and force detectors. In this Letter, we demonstrate a hybrid magnetometer that exploits the coupling between the resonant excitation of spin waves in a ferromagnetic insulator and the resonant excitation of the breathing mechanical modes of a glass microsphere deposited on top. The interaction is mediated by magnetostriction in the ferromagnetic material and the consequent mechanical driving of the microsphere. The magnetometer response thus relies on the spectral overlap between the ferromagnetic resonance and the mechanical modes of the sphere, leading to a peak sensitivity of 850 pT Hz^{-1/2} at 206 MHz when the overlap is maximized. By externally tuning the ferromagnetic resonance frequency with a static magnetic field, we demonstrate sensitivity values at resonance around a few nT Hz^{-1/2} up to the gigahertz range. Our results show that our hybrid system can be used to build a high-speed sensor of oscillating magnetic fields.

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Phys Rev Lett Año: 2020 Tipo del documento: Article País de afiliación: España

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Phys Rev Lett Año: 2020 Tipo del documento: Article País de afiliación: España