Your browser doesn't support javascript.
loading
Associations between Multimodal Fitness Assessments and Rowing Ergometer Performance in Collegiate Female Athletes.
Holmes, Clifton J; Hornikel, Bjoern; Sullivan, Katherine; Fedewa, Michael V.
Afiliación
  • Holmes CJ; Program in Physical Therapy, Washington University School of Medicine, St. Louis, MO 63110, USA.
  • Hornikel B; Department of Kinesiology, University of Alabama, Tuscaloosa, AL 35487, USA.
  • Sullivan K; Department of Kinesiology, University of Alabama, Tuscaloosa, AL 35487, USA.
  • Fedewa MV; Department of Kinesiology, University of Alabama, Tuscaloosa, AL 35487, USA.
Sports (Basel) ; 8(10)2020 Oct 15.
Article en En | MEDLINE | ID: mdl-33076348
The purpose was to examine the association of critical power from a three-minute all-out row (CP3-min) and peak power from a one-stroke maximum test (1-Stroke) with laboratory-based fitness assessments (peak oxygen consumption [V.O2peak] and Wingate anaerobic test [WAnT]) and 6000 m (6K) and 2000 m (2K) rowing ergometer performance. Thirty-one female collegiate rowers (20.2 ± 1.1 years, 70.9 ± 6.9 kg, and 172.2 ± 4.8 cm) participated in fitness and rowing performance testing. Pearson's correlations, linear regression, and Cohen's q were used to determine statistical relationships. Absolute V.O2peak values displayed significant correlations with 6Ktotal (-0.68), 6Ksplit (-0.68), 2Ktotal (-0.64), and 2Ksplit (-0.43). Relative V.O2peak displayed significant correlations with 6Ktotal (-0.36), and 6Ksplit (-0.37). CP3-min demonstrated significant correlations with 6Ktotal (-0.62), 6Ksplit (-0.62), 2Ktotal (-0.61), and 2Ksplit (-0.99). For 2Ksplit, a significant difference was observed between relative V.O2peak and CP3-min correlations with a "large" effect size (q = 2.367). Furthermore, 1-Stroke showed significant associations with 6Ktotal (-0.63), 6Ksplit (-0.63), 2Ktotal (-0.62), and 2Ksplit (-0.44), while WAnT produced non-significant correlations. Absolute V.O2peak CP3-min accounted for significant proportions of variance observed with performance measures (p < 0.05). Practitioners should consider incorporating CP3-min and 1-Stroke as additional tests for gauging rowing performance.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Risk_factors_studies Idioma: En Revista: Sports (Basel) Año: 2020 Tipo del documento: Article País de afiliación: Estados Unidos Pais de publicación: Suiza

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Risk_factors_studies Idioma: En Revista: Sports (Basel) Año: 2020 Tipo del documento: Article País de afiliación: Estados Unidos Pais de publicación: Suiza