Your browser doesn't support javascript.
loading
Endotoxin contamination of single-use sterile surgical gloves.
Takahashi, Gaku; Kan, Shigenori; Hoshikawa, Koichi; Sato, Koutaro; Fujita, Yuji; Inada, Katsuya; Inoue, Yoshihiro.
Afiliación
  • Takahashi G; Department of Critical Care and Disaster, General Medicine, Iwate Medical University, 2-1-1 Idaidori, Yahaba, Siwa, Iwate, 028-3695, Japan.
  • Kan S; Department of Critical Care and Disaster, General Medicine, Iwate Medical University, 2-1-1 Idaidori, Yahaba, Siwa, Iwate, 028-3695, Japan.
  • Hoshikawa K; Department of Critical Care and Disaster, General Medicine, Iwate Medical University, 2-1-1 Idaidori, Yahaba, Siwa, Iwate, 028-3695, Japan.
  • Sato K; Department of Orthopedic Surgery, Iwate Medical University, 2-1-1 Idaidori, Yahaba, Siwa, Iwate, 028-3695, Japan.
  • Fujita Y; Department of Critical Care and Disaster, General Medicine, Iwate Medical University, 2-1-1 Idaidori, Yahaba, Siwa, Iwate, 028-3695, Japan.
  • Inada K; Department of Critical Care and Disaster, General Medicine, Iwate Medical University, 2-1-1 Idaidori, Yahaba, Siwa, Iwate, 028-3695, Japan.
  • Inoue Y; Department of Critical Care and Disaster, General Medicine, Iwate Medical University, 2-1-1 Idaidori, Yahaba, Siwa, Iwate, 028-3695, Japan.
Future Microbiol ; 15: 1425-1430, 2020 10.
Article en En | MEDLINE | ID: mdl-33156702
ABSTRACT

Aim:

Strict endotoxin limits are enforced for implants and catheters inserted into the body. However, no standard limit has been set for single-use sterile surgical gloves. Materials &

methods:

Four types of gloves sold in Japan were dipped in saline and that endotoxin levels were measured. Cytokine producing activity of gloves in blood was also measured.

Results:

Three of the four types of gloves showed endotoxin contamination. We also confirmed an increase in cytokine production in these gloves except one glove in which anionic surfactants was found.

Conclusion:

The extent to which detected endotoxins enter the body during surgery is controversial, but strict endotoxin limits need to be established.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Contaminación de Equipos / Endotoxinas / Guantes Quirúrgicos Límite: Humans Idioma: En Revista: Future Microbiol Asunto de la revista: MICROBIOLOGIA Año: 2020 Tipo del documento: Article País de afiliación: Japón

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Contaminación de Equipos / Endotoxinas / Guantes Quirúrgicos Límite: Humans Idioma: En Revista: Future Microbiol Asunto de la revista: MICROBIOLOGIA Año: 2020 Tipo del documento: Article País de afiliación: Japón