Your browser doesn't support javascript.
loading
Affinity Captured Urinary Extracellular Vesicles Provide mRNA and miRNA Biomarkers for Improved Accuracy of Prostate Cancer Detection: A Pilot Study.
Davey, Michelle; Benzina, Sami; Savoie, Marc; Breault, Guy; Ghosh, Anirban; Ouellette, Rodney J.
Afiliación
  • Davey M; Atlantic Cancer Research Institute, Moncton, NB E1C 8X3, Canada.
  • Benzina S; Atlantic Cancer Research Institute, Moncton, NB E1C 8X3, Canada.
  • Savoie M; Dr. Georges-L.-Dumont University Hospital Centre, Moncton, NB E1C 2Z3, Canada.
  • Breault G; Dr. Georges-L.-Dumont University Hospital Centre, Moncton, NB E1C 2Z3, Canada.
  • Ghosh A; Atlantic Cancer Research Institute, Moncton, NB E1C 8X3, Canada.
  • Ouellette RJ; Atlantic Cancer Research Institute, Moncton, NB E1C 8X3, Canada.
Int J Mol Sci ; 21(21)2020 Nov 06.
Article en En | MEDLINE | ID: mdl-33172003
Serum prostate-specific antigen (sPSA) testing has helped to increase early detection of and decrease mortality from prostate cancer. However, since sPSA lacks specificity, an invasive prostate tissue biopsy is required to confirm cancer diagnosis. Using urinary extracellular vesicles (EVs) as a minimally invasive biomarker source, our goal was to develop a biomarker panel able to distinguish prostate cancer from benign conditions with high accuracy. We enrolled 56 patients in our study, 28 negative and 28 positive for cancer based on tissue biopsy results. Using our Vn96 peptide affinity method, we isolated EVs from post-digital rectal exam urines and used quantitative polymerase chain reaction to measure several mRNA and miRNA targets. We identified a panel of seven mRNA biomarkers whose expression ratio discriminated non-cancer from cancer with an area under the curve (AUC) of 0.825, sensitivity of 75% and specificity of 84%. We also identified two miRNAs whose combined score yielded an AUC of 0.744. A model pairing the seven mRNA and two miRNA panels yielded an AUC of 0.843, sensitivity of 79% and specificity of 89%. Addition of EV-derived PCA3 levels and clinical characteristics to the biomarker model further improved test accuracy. An AUC of 0.955, sensitivity of 86% and specificity of 93% were obtained. Hence, Vn96-isolated urinary EVs are a clinically applicable and minimally invasive source of mRNA and miRNA biomarkers with potential to improve on the accuracy of prostate cancer screening and diagnosis.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Neoplasias de la Próstata / Vesículas Extracelulares Tipo de estudio: Diagnostic_studies / Prognostic_studies / Screening_studies Límite: Aged / Humans / Male / Middle aged Idioma: En Revista: Int J Mol Sci Año: 2020 Tipo del documento: Article País de afiliación: Canadá Pais de publicación: Suiza

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Neoplasias de la Próstata / Vesículas Extracelulares Tipo de estudio: Diagnostic_studies / Prognostic_studies / Screening_studies Límite: Aged / Humans / Male / Middle aged Idioma: En Revista: Int J Mol Sci Año: 2020 Tipo del documento: Article País de afiliación: Canadá Pais de publicación: Suiza