Your browser doesn't support javascript.
loading
[Intraoperative vascular air embolism : Evidence for risks, diagnostics and treatment]. / Intraoperative vaskuläre Luftembolie : Evidenz bei Risiko, Diagnostik und Therapie.
Michels, P; Meyer, E C; Brandes, I F; Bräuer, A.
Afiliación
  • Michels P; Klinik für Anästhesiologie, Universitätsmedizin Göttingen, Robert-Koch-Str. 40, 37099, Göttingen, Deutschland. pmichels@med.uni-goettingen.de.
  • Meyer EC; Klinik für Anästhesiologie, Universitätsmedizin Göttingen, Robert-Koch-Str. 40, 37099, Göttingen, Deutschland.
  • Brandes IF; Klinik für Anästhesiologie, Universitätsmedizin Göttingen, Robert-Koch-Str. 40, 37099, Göttingen, Deutschland.
  • Bräuer A; Klinik für Anästhesiologie, Universitätsmedizin Göttingen, Robert-Koch-Str. 40, 37099, Göttingen, Deutschland.
Anaesthesist ; 70(5): 361-375, 2021 05.
Article en De | MEDLINE | ID: mdl-33196882
ABSTRACT
The entry of gases into the vascular system is called vascular air embolism (VAE). The blocking of the pulmonary circulation by VAE can lead to fulminant right-sided heart failure and cardiocirculatory arrest. A VAE can occur at any time if there is an open connection between the environment and a venous vessel with subatmospheric pressure. This situation occurs during ear nose throat surgery, hip surgery, surgery of the lesser pelvis or breast surgery, if the surgical field is above the level of the heart; however, a VAE can also occur during routine tasks, such as insertion or removal of a central venous catheter or during endoscopic procedures with the insufflation of gas.Because during these procedures VAE is not the main focus of the anesthesia or surgery personnel, in such situations its sudden unexpected occurrence can have severe consequences. In contrast, in cardiac surgery or neurosurgery the risk of intraoperative VAE is much better known. In procedures with a higher risk of a clinically relevant VAE, a patent foramen ovale should be ruled out by preoperative transesophageal echocardiography (TEE). Intraoperatively TEE is the most sensitive procedure not only to detect a VAE but also to visualize the clinical expression, e.g. acute right heart overload.The avoidance of an initial and repeated air embolism is the primary measure to minimize the incidence and severity of VAE.Intraoperatively the following measures should be undertaken excellent communication between anesthesia and surgery personnel with predetermined actions, maintenance of normal volume, patient positioning with minimal difference in height between heart and head, state of the art surgical technique with closure of potential air entry sites, sufficient detection of air by TEE, repeated jugular vein compression during neurosurgery, intraoperative Trendelenburg positioning of the patient during persisting or clinically evident VAE, differentiated adjustment of ventilatory settings and catecholamine treatment, aspiration of the blood-air mixture (air lock) at the junction of the superior vena cava and right atrium through a large bore central venous line and keeping check of the coagulation status.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Embolia Aérea Tipo de estudio: Diagnostic_studies / Etiology_studies / Risk_factors_studies Límite: Humans Idioma: De Revista: Anaesthesist Año: 2021 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Embolia Aérea Tipo de estudio: Diagnostic_studies / Etiology_studies / Risk_factors_studies Límite: Humans Idioma: De Revista: Anaesthesist Año: 2021 Tipo del documento: Article